Technical Manual
Manual must be completed by Installer and left with Home Owner

Questions and Answers

  • M
    Melvin DavisAug 5, 2025
    Why does my strada Storage hot water temperature drop quickly?
    • J
      Juan MaldonadoAug 5, 2025
      Several factors can cause a rapid drop in hot water temperature: If an inhibitor has been installed, ensure with the installer that it has been installed at the correct proportion and checked at appropriate frequencies. The in-line strainer in the cold mains supply to the unit may be choked and require cleaning. Carefully check the hot water temperature flow into the mixing valve. If it is very hot, it may be that the valve needs to be checked / replaced. A competent installer should check the mixing valve for blockages within the internal filter. Scale build up inside the Heat Exchanger Coil, especially if in a known hard water area could be the reason. A competent installer would need to descale the DHW coil and check/fit descaling equipment.
  • D
    Deborah FloresAug 11, 2025
    What to do if my strada Storage water is lukewarm even at 75°C?
    • A
      Angela BoydAug 11, 2025
      If your thermal store is at or approaching 75°C - 80°C, first, verify that the Thermostatic Mixing Valve is correctly set. The maximum temperature of water from the Mixing Valve should be about 55°C. If correctly set, check that the flow rate at any outlet (e.g. bath tap) does not exceed 18 Litres per minute. Excessive flow may hinder sufficient heat transfer; reduce the flow or fit a flow restrictor to increase the temperature. If these steps fail, a qualified installer should inspect the mixing valve for internal blockages.
  • V
    Vincent HoffmanAug 19, 2025
    Why strada Storage doesn't produce enough hot water?
    • Z
      zhouseAug 19, 2025
      Check the heat sources and their input in (kW) to the store. The kW input may be lower than the kW output, preventing the store from producing enough heat for the exchanger to provide heated mains pressure water.
  • M
    Melissa LeeAug 27, 2025
    What does it mean if my strada Storage hot water has a brownish tint?
    • J
      jthomasAug 28, 2025
      A brownish tint in your hot water suggests that the heat exchanger coil is leaking inside the thermal store. An installer should test this. Also, pay attention to the Feed & Expansion Tank, as pressure within the store will increase, causing the tank to overflow continually.

Summary

Technical Manual

Aquatherm Schematic

Aquatherm Connection Heights

Technical Data

Handling & Storage

Mains Water Supply

Discharge;Overflow Requirements

Water Treatment

Commissioning

Immersion Heaters

Troubleshooting

Aquatherm Spares List

Commissioning Checklist

strada Aquatherm STA140UC Specifications

General IconGeneral
Brandstrada
ModelAquatherm STA140UC
CategoryStorage
LanguageEnglish

Related product manuals