SBM-01 high precision battery monitor
19
‘CHARGE BATTERY FULL’
keeps on flashing
(synchronize your battery with
the monitor)
- Check the charged-parameters
in Functions F02, F03 and F04
for possible wrong settings.
State-of-charge and/or time-to-
go readout not accurate
- Check if all current is flowing
through the shunt (the negative
terminal of the battery may only
contain the wire going to the
battery-side of the shunt!).
- Current sense leads from the
shunt are reversed.
- Check battery capacity in
Function F01
- Check CEF in Function F09
- Check Peukert Exponent in
Function F10
- Check Battery temperature in
Function F11
- Check Temperature coefficient
in Function F12
Display returns ‘- - - -‘ in
temperature readout
- Connection with temperature
sensor is lost. Check for failed
connections and/or cable
damage.
Display returns ‘Lo’ repeatedly
regardless of readout selection
- Undervoltage detected. Input
voltage is below the value
entered in Function F07.
Display returns ‘Hi’ repeatedly
regardless of readout selection
- Overvoltage detected. Input
voltage exceeds the value
entered in Function F08.
Battery voltage readout is highly
inaccurate
- Check prescaler setting in
Function F16
If none of the above remedies will help solving the problem you
encounter, it’s best to contact your local dealer for further help.
5.1 Warranty
Studer Innotec (Studer) warrants this product to be free from defects in
workmanship or materials for 24 months from the date of purchase.