IT Cooling Solutions
Index G35
Issue 4.2016
CyberRow
Precision Air Conditioning Units
380-415 V / 3 Ph / 50 Hz
Original instructions
Question and Answer IconNeed help?

Do you have a question about the Stulz CRS 361 AS and is the answer not in the manual?

Stulz CRS 361 AS Specifications

General IconGeneral
BrandStulz
ModelCRS 361 AS
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Information

General Safety Instructions

General safety guidelines for operation and maintenance of the unit.

Refrigerant Handling Safety

Procedures and precautions for working with refrigerants.

Unit Description and Layout

Refrigerant Systems and Electronics

Motors and Control Systems

Control, Monitoring, and Safety Components

Covers safety devices like high pressure switches and sensors.

Technical Data

Application Limits and Conditions

Specifies operational boundaries and conditions for A/C units.

Technical Data - Construction Size S

Specifications for size S units, including cooling capacity.

Technical Data - Construction Size 1

Detailed specifications for construction size 1 units.

Technical Data - Construction Size 2

Detailed specifications for construction size 2 units.

Technical Data - On/Off Compressor Units

Technical data for units with on/off compressors.

Installation Procedures

Unit Positioning Guidelines

Guidelines for optimal placement of CyberRow units in server rooms.

Refrigerant Circuit Installation

Electrical Connections and Start-up

Main Electric Connections

Guidelines for safely connecting the unit to the power supply.

System Start-up Procedure

Procedures for commissioning and initial operation of the system.

µPC Board and PGD1 Terminal

Terminal PGD1 Operation and Configuration

Guides user through operating the PGD1 terminal and configuring unit settings.

Compressor Configuration via PGD1 Terminal

Steps to configure compressor settings using the PGD1 terminal.

PGD1 Compressor Operation Settings

Details on setting pressure limits and failure control via PGD1.

Maintenance Procedures

General Maintenance Safety Instructions

General safety precautions for performing maintenance work.

Refrigerant Circuit Maintenance

Checks for refrigerant charge, HP switch, sight glass, and filter drier.

Malfunctions and Unit Disposal

Common Malfunctions and Troubleshooting

Lists common alarms, their causes, and elimination steps.

Steam Humidifier System

Humidifier Fault Elimination and Maintenance

Troubleshooting guide for malfunctions, error indications, and maintenance resets.

Optional System Features