Questions and Answers

  • B
    bryantwilliamAug 2, 2025
    What to do if my Sturdy SA-300VMA Steriliser says 'E107: USB is full'?
    • C
      calvinhernandezAug 2, 2025
      If the Sturdy Steriliser displays the error 'E107: USB is full', it means the storage medium has reached its maximum data limit. You should immediately back up the data onto a secure zone. Then, follow the procedure '7.5.2.4 Download' to download the last record.
  • B
    brandigonzalesAug 7, 2025
    Why does the display of my Sturdy Steriliser not turn on?
    • B
      Brian PetersonAug 7, 2025
      If the Sturdy Steriliser shows no display, first, ensure that the main switch is turned on. Next, check if the power cable is properly plugged in. Also, verify that there are no bad connections. If the problem persists, contact your local distributor for service.
  • J
    Julie RileyAug 11, 2025
    What to do if my Sturdy SA-300VMA Steriliser displays 'E108: USB formatter error'?
    • F
      Francis FarmerAug 11, 2025
      If your Sturdy Steriliser displays the error 'E108: USB formatter error', try re-formatting the USB flash drive. If that doesn't work, replace it with another USB flash drive. If the problem continues, contact your local distributor for service.
  • F
    ffordAug 15, 2025
    What to do if my Sturdy Steriliser displays 'E105: No USB memory'?
    • D
      desireestuartAug 15, 2025
      If the Sturdy Steriliser displays 'E105: No USB memory', insert a USB flash drive. If a USB drive is already inserted, detach and re-insert the memory card again.
  • E
    Elizabeth AdamsAug 20, 2025
    What to do if my Sturdy Steriliser displays 'E135: Abnormal of the cycle'?
    • K
      Kimberly WalkerAug 20, 2025
      If your Sturdy Steriliser displays the error 'E135: Abnormal of the cycle', check the power supply to the Autoclave. If the issue persists, contact your local distributor for service.
  • S
    Scott SalasAug 25, 2025
    What to do if my Sturdy Steriliser displays 'E109: EEPRM fail'?
    • P
      Patricia VelezAug 25, 2025
      If the Sturdy Steriliser displays the error 'E109: EEPRM fail', replace the USB flash drive with another one. If the problem continues, contact your local distributor for service.
  • S
    slloydAug 28, 2025
    What to do if my Sturdy SA-300VMA displays 'E155: Password fail'?
    • C
      Casey RyanAug 28, 2025
      This function is reserved for diagnostic purposes by the manufacturer and is password protected. Contact your local distributor or the manufacturer for information.

Summary

Important Safety Instructions

Explanation of Safety Symbols and Notes

Unpacking

Installation

Environment

Details installation environment requirements for optimal performance and interference elimination.

Install the Sterilizer

Step-by-step guide for physically placing and connecting the sterilizer unit.

Introduction

Intended Use

Specifies the product's purpose and application for sterilization of various items.

Description of the Sterilizer

Details the physical components and features of the autoclave sterilizer.

Operation

Operation Overview and Programs

Outlines general operation, Re-Dry, Liquid programs, and test cycles.

Sterilization Preparation and Standard Cycle

Guides on preparing for sterilization and running the standard sterilization program.

Specialized Programs and Safety Operations

Covers advanced programs, safety features, and item placement.

Recorder (SA-300 VMA-R)

Recorder Overview and Data

Explains the recorder's purpose, intended use, and the data it captures.

Recorder Panel, Functions, and Setup

Details the recorder's controls, display, operational modes, and configuration.

Recorder Data Management and Troubleshooting

Covers downloading data, printer settings, and resolving recorder issues.

Test Instructions

Biological Performance of Sterilizers

Explains biological indicators for validating sterilization cycles.

Air Removal (Bowie-Dick Type Test Pack)

Details the procedure for performing the Bowie-Dick test for air removal.

Helix Test

Describes the process and interpretation of the Helix test for load penetration.

Maintenance Instructions

Daily and Weekly Maintenance

Provides daily and weekly cleaning and inspection procedures for the sterilizer.

Monthly and Annual Maintenance

Details monthly cleaning and annual checks, including gasket replacement.

Troubleshooting

Symptoms and Causes

Lists common problems encountered with the sterilizer and their potential causes.

List of Error Codes

Provides a comprehensive list of error codes and their meanings.

Specifications

Warranty

Sturdy SA-300VMA Specifications

General IconGeneral
BrandSturdy
ModelSA-300VMA
CategorySteriliser
LanguageEnglish