Torque Control Verifier Ethernet 2
2.4GHz FM TCVe2 User Manual
Part Number 857414 Rev A
01 July 2020
Question and Answer IconNeed help?

Do you have a question about the Sturtevant Richmont TCVe2 and is the answer not in the manual?

Summary

Quick Start Guide

Warnings

Cautions

Unit Overview

Compatible Tools

Using The Unit

Concepts

Explains interfaces and tool association with the TCVe2.

Run Screen

Details the main display screen and its indicators.

Configuring The Unit

Tool Info Group

Manages learned tools: view details and select, forget, or edit parameters.

Common Fields

Explains common parameter fields like Interface assignment and Batch count.

TAC Fields

Mode

Sets the torque determination mode (Peak or TAM) for TAC tools.

Autoclear Time

Duration torque must remain steady for reporting.

Dwell Time

Time allowed for reseating or ratcheting the tool.

Head Length

Defines the tool head's centerline length for accurate measurements.

Torque Unit

Selects units for torque measurements (in.lb, N.m, etc.).

Snug Torque

Torque threshold for initiating angle measurement.

Min Torque

Sets the minimum acceptable torque for a valid tightening.

Click Tool Fields

Max Torque

Sets the maximum acceptable torque for a valid tightening.

Min Angle

Sets the minimum acceptable angle for a valid tightening.

Max Angle

Sets the maximum acceptable angle for a valid tightening.

Timer Min

Minimum time tool must be held in clicked position for valid tightening.

Timer Max

Maximum time tool can be held in clicked position for valid tightening.

TBC (Time between cycles)

Minimum time required between consecutive accepted tightenings.

TBB (Time between batches)

Serial Number

Status Info Group

Network Connection Info Group

IP Info Group

IP Address

Configures the qualifier's IP address for Ethernet networks.

Subnet Mask

Configures the subnet mask for Ethernet networks.

Gateway

Configures the default gateway for Ethernet networks.

Edit Password

Sets or changes the unit's access password.

XBEE Channel

Sets the radio channel for tool communication.

Reset Defaults

Open Protocol

Port Number

Sets the network port for Open Protocol connections to Interface 1 and 2.

Message Timeout

Time the qualifier waits for a response to subscription notifications.

Resend Attempts

Number of times notification packets are resent upon no response.

Keep Alive

Duration a connection remains open without commands to prevent closure.

OP Cmd Enable

Cell ID

Channel ID

ToolsNet

Int 1 Enabled

Enables ToolsNet connection establishment for Interface 1.

Int 2 Enabled

Enables ToolsNet connection establishment for Interface 2.

PIM Address

IP address of the PIM server for ToolsNet connections.

PIM Port

Port number of the PIM server for ToolsNet connections.

PIM Retry Interval

Time to wait after a failed ToolsNet connection attempt before retrying.

Result Timeout

Time to wait for a response from the ToolsNet server.

Keep Alive

System Number

Station Number

Retries

PFCS Setup

Interface 1 Settings

Configuration for PFCS Interface 1, including solicited/unsolicited, auto, and name settings.

Interface 2 Settings

Configuration for PFCS Interface 2, including solicited/unsolicited, auto, and name settings.

PFCS Ports

Defines the solicited and unsolicited ports for PFCS interfaces.

Server Address

IP address of the PFCS server for connection.

ACK Timeout

Time qualifier waits for response from the PFCS client.

Retries

Number of times to resend packets before PFCS connection is broken.

Keep Alive

Controls how often a keep alive packet is sent to the PFCS server.

Parameter Name

Specifies the parameter name used in PFCS.

Studio 5000 Add-On Instructions

Connection Points

Defines points for data exchange between TCVe2 and Studio 5000 via EtherNet/IP.

Output (O->T) Connection Points

Points used by TCVe2 to receive input data from the network for control.

Input (T->O) Connection Points

Input Connection Points for Last Tightening Data

Connection points detailing the last tightening event's data.

Input Connection Points for Current Operation Status

TCVe2 Setup in Studio 5000

Importing the EDS file

Step-by-step guide to import the TCVe2 EDS file into Studio 5000.

Project Setup

Discrete I;O

Electrical Specifications

Technical specifications for opto-isolated inputs and relay outputs.

I;O Function Assignment

Default configuration and assignment of inputs and outputs.

Data Management

Read;Write

Downloading results/logs and uploading firmware via USB.

Tightenings

Saving tightening results files (CSV) to USB.

Configuration

Saving unit configuration settings (g4t) to USB.

Network Log

Saving network log data (net.g4n) to USB.

Barcode Reader

Functionality, format, and commands for barcode scanning.

Firmware Updates

Product Specification

Dimensions

Physical dimensions of the TCVe2 unit in English and Metric units.

Radio Information

Details on radio range, transmit power, and receiver sensitivity.

FCC Statement

FCC compliance information and conditions for operation.

Channel Frequencies

List of channel frequencies used by the wireless communication.

Sturtevant Richmont TCVe2 Specifications

General IconGeneral
BrandSturtevant Richmont
ModelTCVe2
CategoryControl Systems
LanguageEnglish