Do you have a question about the Sturtevant Richmont TCVe2 and is the answer not in the manual?
Explains interfaces and tool association with the TCVe2.
Details the main display screen and its indicators.
Manages learned tools: view details and select, forget, or edit parameters.
Explains common parameter fields like Interface assignment and Batch count.
Sets the torque determination mode (Peak or TAM) for TAC tools.
Duration torque must remain steady for reporting.
Time allowed for reseating or ratcheting the tool.
Defines the tool head's centerline length for accurate measurements.
Selects units for torque measurements (in.lb, N.m, etc.).
Torque threshold for initiating angle measurement.
Sets the minimum acceptable torque for a valid tightening.
Sets the maximum acceptable torque for a valid tightening.
Sets the minimum acceptable angle for a valid tightening.
Sets the maximum acceptable angle for a valid tightening.
Minimum time tool must be held in clicked position for valid tightening.
Maximum time tool can be held in clicked position for valid tightening.
Minimum time required between consecutive accepted tightenings.
Configures the qualifier's IP address for Ethernet networks.
Configures the subnet mask for Ethernet networks.
Configures the default gateway for Ethernet networks.
Sets or changes the unit's access password.
Sets the radio channel for tool communication.
Sets the network port for Open Protocol connections to Interface 1 and 2.
Time the qualifier waits for a response to subscription notifications.
Number of times notification packets are resent upon no response.
Duration a connection remains open without commands to prevent closure.
Enables ToolsNet connection establishment for Interface 1.
Enables ToolsNet connection establishment for Interface 2.
IP address of the PIM server for ToolsNet connections.
Port number of the PIM server for ToolsNet connections.
Time to wait after a failed ToolsNet connection attempt before retrying.
Time to wait for a response from the ToolsNet server.
Configuration for PFCS Interface 1, including solicited/unsolicited, auto, and name settings.
Configuration for PFCS Interface 2, including solicited/unsolicited, auto, and name settings.
Defines the solicited and unsolicited ports for PFCS interfaces.
IP address of the PFCS server for connection.
Time qualifier waits for response from the PFCS client.
Number of times to resend packets before PFCS connection is broken.
Controls how often a keep alive packet is sent to the PFCS server.
Specifies the parameter name used in PFCS.
Defines points for data exchange between TCVe2 and Studio 5000 via EtherNet/IP.
Points used by TCVe2 to receive input data from the network for control.
Connection points detailing the last tightening event's data.
Step-by-step guide to import the TCVe2 EDS file into Studio 5000.
Technical specifications for opto-isolated inputs and relay outputs.
Default configuration and assignment of inputs and outputs.
Downloading results/logs and uploading firmware via USB.
Saving tightening results files (CSV) to USB.
Saving unit configuration settings (g4t) to USB.
Saving network log data (net.g4n) to USB.
Functionality, format, and commands for barcode scanning.
Physical dimensions of the TCVe2 unit in English and Metric units.
Details on radio range, transmit power, and receiver sensitivity.
FCC compliance information and conditions for operation.
List of channel frequencies used by the wireless communication.