20
|
English
BUILT-IN REFRIGERATION
Dual Installation
If two units are installed side by side, a dual installation kit
may be required. Installations without a custom ller strip
require a dual installation kit. If a dual installation kit is not
specied, a 51 mm ller strip is recommended between
units. A custom ller strip is required when installing two
French door or side-by-side models. Dual installations
without a ller strip can only be accomplished using two
units with opposite hinges. Refer to the illustrations below.
Dual installation kits are available through an authorized
Sub-Zero dealer. For questions regarding the installation,
contact your authorized Sub-Zero dealer.
WITHOUT FILLER STRIP
FILLER STRIP
Opposite hinges.
Same side hinges.
For dual standard installations, panel dimensions are the
same as for single installations. Refer to the charts on pages
15–16. Panel dimensions and offsets for dual ush inset
installations are listed on the following pages.
WINE INTEGRATED PRO 48 BUILT-IN