EasyManuals Logo

Sub-Zero UC-15I Installation Guide

Sub-Zero UC-15I
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
Ice Machine Specifications 5
subzero.com/specs
E
E
E
Location of electrical supply.
T
he electrical supply for the ice machine must be installed
by a qualified electrician in accordance with all applicable
national and local electrical codes. Observe the following:
The ice machine must be grounded in accordance with
national and local electrical codes.
A separate fuse or circuit breaker must be provided for
each ice machine.
The maximum allowable voltage variation is ±10% of
the rated voltage at ice machine start-up, when the
electrical load is highest.
The minimum wire size is #14 for less than 100'
(31 m)
or #12 for more than 100' (31 m) to 200' (61 m), use solid
copper conductor only. The recommended breaker is
15 amp. Local or state electrical code, length of run or
materials used, can increase the minimum wire gauge
required. A qualified electrician must determine the
proper wire size, although #14 is the minimum size
allowed.
The minimum circuit requirement is used to help select
the wire size of the electrical supply. Minimum circuit
requirement is not the ice machine’s running amp load.
Observe correct polarity of incoming line voltage.
Incorrect polarity can lead to erratic ice machine opera-
tion and a safety issue.
Electrical Requirements
T
he ice machine must be installed with adequate clear-
ance for electrical connection at the rear of the unit. The
electrical supply for the ice machine requires installation of
a grounded receptacle on a separate circuit, servicing only
this appliance. Follow the National Electrical Code and
local codes and ordinances when installing the receptacle.
IMPORTANT NOTE: Although it can be located anywhere
on the back wall, it is recommended that the receptacle be
placed in an adjacent cabinet or in the lower right of the
opening. If it is placed within the opening, additional
cabinet depth may be required. Refer to the illustration
below.
Models UC15IO and UC-15IPO are designed and safe for
use in outdoor applications. When installed outdoors, a
ground fault circuit interrupter (GFCI) is required to reduce
the risk of electrical shock. For outdoor models, or if a
ground fault circuit interrupter (GFCI) is required by local
codes, it must be a breaker type, not an outlet type.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Receptacle 3-prong grounding-type
Circuit Breaker 15 amp
Minimum Circuit 4.1 amp
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance.

Other manuals for Sub-Zero UC-15I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sub-Zero UC-15I and is the answer not in the manual?

Sub-Zero UC-15I Specifications

General IconGeneral
BrandSub-Zero
ModelUC-15I
CategoryIce Maker
LanguageEnglish

Related product manuals