CARE RECOMMENDATIONS
Maintenance
PROLONGED SHUTDOWN
If the ice machine is to be removed from service for an
extended period or exposed to temperatures of 32°F
(0°C)
or below, follow the procedure for prolonged shutdown and
winterization.
Prolonged shutdown and winterization procedure:
1 Perform the cleaning and sanitizing procedure on page 7
to prevent mildew growth.
2 Disconnect electrical power at the circuit breaker or
service panel.
3 Turn off the water supply.
4 Remove water from the water reservoir.
5 Disconnect the incoming water supply line at the rear of
the unit and allow it to drain.
6 Disconnect the vinyl hose from the water pump and
allow it to drain.
7 Verify water is not trapped in any of the water supply or
drain lines. Compressed air can be used to blow out the
lines.
8 Use a spray bottle with a solution of 1 tablespoon (15 ml)
sanitizer to 1 gallon
(3.8 L) water and spray all interior
surfaces. Do not rinse, allow it to air dry.
9 Block the door partially open to provide air exchange
and prevent mildew growth.