9-4
Technical Data
7011902 - Revision A - October, 2009
International Integrated
International Integrated
(ICB700 Base)
(ICB700 Base)
Series
Series
Model ICB700BFI
FREEZER
CHARGE (R-134a Refrigerant)
NOTE: Always check serial tag for exact charge
NORMAL OPERATING PRESSURES
Low Side
High Side
COMPRESSOR
NOTE: Always check current parts price list for possible substitutions.
Original/Service Compressor Amps
Original/Service Compressor BTU/H
DEFROST METHOD
DEFROST TERMINATOR
Cut-In Temp.
Cut-Out Temp.
DEFROST HEATER
Watts
Amps
Resistance/Ohms
DRAIN TUBE HEATER
Watts
Mili-Amps
Resistance/Ohms
FILL TUBE HEATER
Watts
Mili-Amps
Resistance/Ohms
WATER VALVE
Watts
Amps
Resistance/Ohms (Inductive)
THERMISTORS
(Evap & Compartment) Resistance/Ohms at 0°C / 32°F
0.17 Kg.
5”-1 psi to 6-15 psi
75 psi to 120 psi
~ 0.65 / ~ 0.65
665 / 665
“Adaptive Defrost”
Defrost intervals and
duration vary by unit use.
5 minute compressor
delay after each defrost.
-1°C / 30°F
21°C / 70°F
490
2.05 - 2.25
85 - 120
7
25 - 35 mA
7800 - 8310
7.2
25 - 35 mA
6600 - 8100
50
0.22
950 - 1200
30000 - 33000