9
FIN DE L'ÉCHAPPEMENT
BOUCHE D'ADMISSION D'AIR
X
SECTEUR OÙ LES SORTIES NE SONT PAS PERMISES
A=
ESPACE LIBRE AU-DESSUS DU SOL, DES
VÉRANDAS, DES PORCHES, DES PATIOS OU
DES BACLCONS
12 POUCES (30 cm)
(VOIR LA NOTE A)
12 POUCES (30 cm)
(VOIR LA NOTE A)
J=
ESPACE LIBRE PAR RAPPORT À L'ENTRÉE
NON MÉCANIQUE DANS L'IMMEUBLE OU
L'ENTRÉE D'AIR DE COMBUSTION À
N'IMPORTE QUEL AUTRE APPAREIL
ÉLECTROMÉNAGER
INSTALLATIONS CANADIENNES
INSTALLATIONS AMÉRICAINES
1 2
6 POUCES (15 cm) POUR LES APPAREILS
ÉLECTROMÉNAGERS DE <10
6 POUCES (15 cm) POUR LES APPAREILS
ÉLECTROMÉNAGERS DE <10 000 Btu/h (3kw))
9 POUCES (23 cm) POUR LES APPAREILS
ÉLECTROMÉNAGERS DE >10 000 Btu/h 93 kW)) ET DE <50
000 Btu/h (15 kW))
12 POUCES (30 cm) POUR LES APPAREILS
ÉLECTROMÉNAGERS DE >50 000 Btu/h (15 kW))
B=
ESPACE LIBRE PAR RAPPORT AUX
FENÊTRES OU AUX PORTES QUI PEUVENT
S'OUVRIR
6 POUCES (15 cm) POUR LES APPAREILS
ÉLECTROMÉNAGERS
<10 000 Btu/h (3 kW)
12 POUCES (30 cm) POUR LES APPAREILS
ÉLECTROMÉNAGERS DE >10 000 btu/h (3
kW))
ET <100 000 Btu/h (30 kW)
INSTALLATIONS CANADIENNES
INSTALLATIONS AMÉRICAINES
1 2
6 POUCES (15 cm) POUR LES APPAREILS
ÉLECTROMÉNAGERS DE <10 000BtU/h (3 kW))
9 POUCES (32 cm) POUR LES APPAREILS
ÉLECTROMÉNAGERS DE
K=
ESPACE LIBRE PAR RAPPORT À L'ENTRÉE
MÉCANIQUE D'ALIMENTATION EN AIR
6 PIEDS (1,83 cm) 3 PIEDS (91 cm) AU-DESSUS SI LA DISTANCE HORIZONTALE
EST DE 10 PIEDS (3 m)
C=
ESPACE LIBRE PAR RAPPORT AUX
FENÊTRES OU AUX PORTES QUI PEUVENT
S'OUVRIR
* a * a
L=
ESPACE LIBRE AU-DESSUS DES TROTTOIRS
PAVÉS OU DES ENTRÉES PAVÉES SITUÉES
SUR DES PROPRIÉTÉS PUBLIQUES
7 PIEDS (2,13 cm)
* a
D=
ESPACE LIBRE À LA VERTICALE PAR RAPPORT
AU PAREMENT VENTILÉ SITUÉ AU-DESSUS
DE LA SORTIE À
* a * a
M=
ESPACE LIBRE SOUS LES VÉRANDAS, LES
PROCHES, LES PATIOS OU LES BALCONS
12 POUCES (30 cm)
* a
E=
ESPACE LIBRE PAR RAPPORT AU PAREMENT NON
VENTILÉ
* a * a
F=
ESPACE LIBRE PAR RAPPORT À UN COIN EXTÉRIEUR
* a * a
G=
ESPACE LIBRE PAR RAPPORT À UN COIN INTÉRIEUR
* a * a
H=
ESPACE LIBRE PAR RAPPORT À CHAQUE CÔTÉ
DE LA LIGNE CENTRALE SE PROLONGEANT
AU-DESSUS DE COMPTEUR/DÉTENDEUR
3 PIEDS (91 cm) PAR RAPPORT
* a
I=
ESPACE LIBRE PAR RAPPORT À LA SORTIE
D'ÉCHAPPEMENT DU RÉGULATEUR DE
SERVICE
3 PIEDS (91 cm)
* a
1
CONFORMÉMENT À LA NORME CSA/ACNOR B149.1 EN VIGUEUR POUR LE GAZ NATUREL ET LE CODE D'INSTALLATION DU PROPANE.
2
CORFORMÉMENT AUX NORMES ANSI Z2231.1/NFPA 54 EN VIGUEUR, POUR LE CODE NATIONAL DU GAZ COMBUSTIBLE.
UN ÉVENT NE DOIT PAS SE SITUER DIRECTEMENT AU-DESSUS D'UN TROTTOIR OU D'UNE ENTRÉE PAVÉE SITUÉE ENTRE DEUX UNITÉS DE LOGEMENT UNIFAMILIALES
ET DESSERVIR LES DEUX UNITÉS.
PERMIS UNIQUEMENT SI LA VÉRANDA, LE PORCHE, LE PATIO OU LE BALCON EST ENTIÈREMENT OUVERT SUR AU MOINS DEUX CÔTÉS SOUS LE NIVEAU DE L'ÉTAGE.
POUR AVOIR LES ESPACES LIBRES NON PRÉCISÉS DANS LES NORMES ANSI Z223.1/NFPA 54 OU CAS/ACNOR B149.1, L'UN DES RENSEIGNEMENTS CI-DESSOUS DOIT
ÊTRE INDIQUÉ:
*
UNE RÉFÉRENCE À LA NOTE DE BAS DE PAGE CI-DESSOUS :
L'ESPACE LIBRE CONFORMÉMENT AUX CODES LOCAUX D'INSTALLATION ET LES EXIGENCES CONTENUES DANS LES INSTRUCTIONS DU FOURNISSEUR DE GAZ
ET DES FABRICANTS (VOIR LE MANUEL FOURNI AVEC L'APPAREIL).
a)
MOBILE
FIXE
FERMÉ
FIXE
FERMÉ
DÉTAILS DE
COIN INTÉRIEUR
G
MOBILE
A
C
F
B
B
B
B
A
J
B
I
H
M
K
E
D
L
B
Figure 8

Other manuals for Suburban DYNAPACK H Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suburban DYNAPACK H Series and is the answer not in the manual?

Suburban DYNAPACK H Series Specifications

General IconGeneral
BrandSuburban
ModelDYNAPACK H Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals