1 Suburban DynaPack H Series Owner's Manual 10/2017 Rev.4
WARNING! If the information in these instructions are not followed exactly, a re or
explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach a gas supplier, call the re department.
Installation and service must be performed by a qualied
installer, service agency or the gas supplier.
WARNING! Improper installation, adjustment, alteration, service or maintenance can
cause property damage, personal injury or loss of life. Refer to the installation instructions
and/or owners manual provided with this appliance. Installation and service must be
performed by a qualied installer, service agency or the gas supplier.
WARNING! Installation and servicing of air conditioning equipment can be hazardous
due to internal refrigerant pressure and live electrical components. Only trained and
qualied service personnel should install or service this equipment. Installation and service
performed by unqualied persons can result in property damage, personal injury, or death.
WARNING! For SAFE operation this must be installed using only the approved exterior
grille and wall sleeve accessories. Failure to comply with this may result in property
damage, personal injury, or death.
CAUTION: The installation of this appliance must conform to the requirements
of the National Fire Protection Association; the National Electrical Code, ANSI/
NFPA No. 70 (latest edition) in the United States; the Canadian Electrical Code
part 1, CSA 22.1 (latest edition) in Canada; and any state or provincial laws
or local ordinances. Local authorities having jurisdiction should be consulted
before installation is made. Such applicable regulations or requirements take
precedence over the general instructions in this manual.
INSPECTING FOR FREIGHT DAMAGES
Your unit was carefully packed in a container which complies with the National
Safe Transit Test. This means that the packaged product, with normal handling,
will withstand the load conditions encountered in normal transit and in handling.
Your unit should be inspected immediately after unpacking to determine if any
damage is present due to shipping or handling. If any damage is discovered,
do not install the unit. Notify the transportation company immediately and le a
damage claim.
The manufacturer can bear no responsibility for damages which occur in transit or
for improper operation of the unit as a result of shipping damages.
AIRXCEL, INC.
SUBURBAN APPLIED PRODUCTS
156 Seedling Drive
Cordele, GA 31015
(229) 273-3636
www.SuburbanManufacturing.com
DYNAPACK "H" SERIES
MODELS
DYPA12AC1A039H
DYPA18AC1A039H, DYPA18AC1A052H
DYPA24AC1A039H, DYPA24AC1A052H
DYPA30AC1A039H, DYPA30AC1A052H
DYPA36AC1A039H, DYPA36AC1A052H
VERTICAL PACKAGED AIR CONDITIONER FEATURING GAS HEAT AND ELECTRIC COOLING
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS
Installer: Leave this manual with the appliance
Consumer: Retain this manual for future reference.
This book contains instructions for installation and operation of your unit. Keep it in a safe place for ready reference.
Should you require further information, contact your dealer.
For future reference, you should record the following information from the units.
MODEL NUMBER _________________________________________________
SERIAL NUMBER _________________________________________________
STOCK NUMBER _________________________________________________
DATE OF PURCHASE _____________________________________________
UNIT SPECIFICATIONS
Do not operate this unit during construction as this may violate your
warranty.
HEATING
MODEL
DYPA
12AC1A039H
DYPA
18AC1A039H
DYPA
24AC1A052H
DYPA
30AC1A052H
DYPA
36AC1A052H
BTU INPUT
39,000 39,000 52,000 52,000 52,000
VOLTS 208-230 208-230 208-230 208-230 208-230
AMPS 4.7 4.7 4.7 4.7 4.7
GAS
CONNECTION
1
/
2
Inch Pipe at Unit
COOLING
MODEL
DYPA
12AC1A039H
DYPA
18AC1A039H
DYPA
24AC1A052H
DYPA
30AC1A052H
DYPA
36AC1A052H
COOLING
CAPACITY
12,000 17,000 23,600 28,400 34,800
VOLTS 208-230 208-230 208-230 208-230 208-230
WATTS 1175 1665 2380 2820 3480
MCA* 13.3 14.9 17.8 21.6 25.2
REFRIGERANT
R410A
REFRIGERANT
CHARGE
SEE INFORMATION
STICKER ON UNIT
*MCA= Minimun Circuit Ampacity
Part Number 205096
10/2017 Rev. 4

Other manuals for Suburban DynaPack S Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suburban DynaPack S Series and is the answer not in the manual?

Suburban DynaPack S Series Specifications

General IconGeneral
BrandSuburban
ModelDynaPack S Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals