CAUTIONS & SAFETY INFORMATION
1. Never use a battery charger to power or test an electronic ignition furnace as they sometimes provide more than
14.5 DC Volts that could damage the module board.
2. Never operate the furnace with the electrode wire disconnected nor with the electrode assembly removed from the furnace.
3. Never use a screwdriver on any part of the electrode assembly while the furnace is in operation.
4. Be certain that the spark from the electrode never reaches the flame sensor portion of the electrode assembly on remote sense
units.
5. Install the furnace so electrical components and connections are protected from water.
6. Wire the furnace direct to the battery when possible.
7. Use two wrenches on gas fittings when tightening gas connections.
8. Verify voltage of furnace, do not use 120 volt AC with 12 volt DC.
9. Do not modify the furnace in any way.
10. Do not vent the furnace to an outside enclosed porch area or where the vent is covered or obstructed.
11. Always meet or exceed minimum duct requirements. Also meet the minimum return air requirements.
12. Furnace must be installed and vented correctly. Refer to the Installation Manual for the specific model furnace.
13. Do not install aftermarket components.

Other manuals for Suburban SF-30F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suburban SF-30F and is the answer not in the manual?

Suburban SF-30F Specifications

General IconGeneral
BTU Output30, 000 BTU
TypeForced Air
IgnitionDirect Spark Ignition
Voltage12V DC
Fuel TypePropane
Efficiency80%