ADVANCED
Single unit connection
MASTER-SLAVE system connection
Warning: during this stage all the products must have the main switch set on “0”.
Warning: Humidity and twilight sensors will detect the values from the first unit connected.
In case of a system with long wires or with a lot of electric/electronic equipment may cause
signal disturbance to use shielded cables and connect a termination resistor of 120ohm on
pin 3 and 4 of the terminal block of the last SLAVE.
WIRELESS
Products connections
Warning: during this stage all the products must have the main switch set on “0”.