SRC-- 1 5 0 --- S RC -- 1000
Technical data / Caractéristiques techniques / Datos técnicos
Electrical
supply inlet
Compressor Fan motor Pump
Minimum
circuit ampacity
Maximum
protection device rating
Minimum section
validated cable for eletrical
connection
1 MC1 3 EV1 9 P MCA HACR
RLA LRA FLA
FLA
∅
(A) (A) (A)
(HP)
(A)
(HP) (
) (
)
115/1/60 12.5 64.5 2.00 0.29 0.76 1/25 18.39 25
S
C-- 150
230/1/60 5.8 30 0.60 0.19 0.76 1/25 8.61 10
SRC-- 175 230/1/60 7.7 38 0.60 0.19 0.76 1/25 10.99 15
W
SRC-- 200 230/1/60 7.7 38 0.60 0.19 0.76 1/25 10.99 15
230/3/60 6 45.5 1.30 0.70 1.17 1/15 10.1 15 3x12AWG
S
C-- 250
460/3/60 5 31 0.74 0.70 1.17 1/15 8.16 10 3x14AWG
230/3/60 6 45.5 1.30 0.70 1.17 1/15 10.1 15 3x12AWG
S
C-- 325
460/3/60 5 31 0.74 0.70 1.17 1/15 8.16 10 3x14AWG
230/3/60 7.6 65.5 1.30 0.70 1.17 1/15 12.1 15 3x12AWG
S
C-- 400
460/3/60 5 31 0.74 0.70 1.17 1/15 8.16 10 3x14AWG
230/3/60 7.6 65.5 1.30 0.70 1.17 1/15 12.1 15 3x12AWG
S
C-- 500
460/3/60 5 31 0.74 0.70 1.17 1/15 8.16 10 3x14AWG
230/3/60 13.2 91 1.30 0.90 1.17 1/15 19.1 15
S
C-- 700
460/3/60 7.9 50 1.25 1.07 1.17 1/15 12.295 20
SRC-- 850 460/3/60 10 63 1.90 1.54 1.17 1/15 15.57 20
W
SRC-- 1000 460/3/60 10 63 1.90 1.54 1.17 1/15 15.57 20
Calibration values Fan pressure switch High pressure switch Low pressure switch
PV HP LP
S
C-- 150 --- S
C-- 200
ON: 261 PSIg
---
SRC-- 250 --- SRC -- 1000
:
g
ON: 18 bar
OFF: 14 bar
28 bar
21.7 --- 36.2 PSIg
1 . 5 --- 2 . 5 b a r