EasyManua.ls Logo

Summit Commercial BIM-44 G - User Manual

Default Icon
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Users Manual (pages 1 - 26)
Manual del usuario (páginas 27 a 52)
Be sure ice maker is standing upright 24 hours prior to plug-in.
Asegúrese que la máquina esté parada en posición vertical 24 horas antes que sea conectada.
Model/Modelo
BIM-44 G
Automatic Undercounter Ice Maker
Máquina automática para hacer hielo
SUMMIT
®
APPLIANCE DIVISION
Felix Storch, Inc.
770 Garrison Avenue
Bronx, NY 10474
Website: www.summitappliance.com

Table of Contents

Questions and Answers

  • J
    Jerry BakerAug 15, 2025
    What to do if my Summit Commercial BIM-44 G Ice Maker stops suddenly?
    • T
      Timothy LopezAug 15, 2025
      If your Summit Commercial Ice Maker stops suddenly while making ice, there are a few potential causes. First, check if the electricity is off and reconnect the power supply line if needed. Second, the room temperature might be out of the recommended range; if so, disconnect the ice maker until the temperature returns to normal. Finally, the ice storage bin might be full, in which case you should remove some ice and ensure the ice-full probe is free of ice.
  • J
    Jake CobbAug 19, 2025
    Why is my Summit Commercial BIM-44 G leaking water?
    • D
      David HouseAug 19, 2025
      There could be several reasons why your Summit Commercial Ice Maker is leaking water. If water falls to the floor when opening the door to remove ice, it's likely normal condensation. Check if the water supply connection is leaking and tighten the fitting if necessary. Also, ensure the drain pipe is lower than the drain outlet.
  • A
    Ashley MillerAug 21, 2025
    What to do if water doesn't feed into my Summit Commercial BIM-44 G Ice Maker?
    • M
      Maria EllisAug 22, 2025
      If water isn't feeding into your Summit Commercial Ice Maker after it starts, check that the water supply tap is turned on. Also, make sure the water supply pipe is properly connected; if not, reconnect it.
  • R
    Ronald WilliamsAug 26, 2025
    Why does scaling occur frequently inside my Summit Commercial BIM-44 G Ice Maker?
    • T
      Tammy StoutAug 26, 2025
      If scaling occurs frequently inside your Summit Commercial Ice Maker, it's likely that the hardness level of the water is too high. Consider installing a water-softening device in front of the water inlet.
  • C
    Cory JordanAug 28, 2025
    Why my Summit Commercial BIM-44 G doesn’t operate?
    • K
      Kiara HaleAug 29, 2025
      There are several reasons why your Summit Commercial Ice Maker might not be operating. It could be unplugged, so ensure it is properly plugged in. The fuse might be blown, in which case you should replace it; if this happens repeatedly, call for service. Also, check that the power button is switched to the 'ON' position. Lastly, if the ice storage bin is full, remove some ice to ensure the ice-full probe is not obstructed.
  • B
    Bryan FreemanAug 31, 2025
    Why my Summit Commercial Ice Maker makes ice, but the bin doesn't fill?
    • C
      Charles GreeneAug 31, 2025
      If your Summit Commercial Ice Maker is making ice, but the bin isn't filling up, it could be due to a few reasons. The condenser might be dirty, so try cleaning it. Additionally, the airflow to the ice maker might be obstructed, so check the installation. High ambient and water temperatures, or proximity to a heat source, can also cause this issue, so review the installation.
  • W
    William OrtizSep 4, 2025
    Why are my Summit Commercial BIM-44 G Ice Maker's ice cubes partially formed?
    • C
      Carmen ArmstrongSep 4, 2025
      If the ice cubes from your Summit Commercial Ice Maker are partially formed or white on the bottom, it could be due to insufficient water in the water trough. Check if the water supply pressure is below 15 psig. Also, the water supply or filter may be restricted. Finally, check for a water leak at the water trough.
  • S
    Stacey YoungSep 7, 2025
    Why is water leaking from the ice storage bin of my Summit Commercial BIM-44 G Ice Maker?
    • W
      William AdkinsSep 7, 2025
      If water is leaking from the ice storage bin of your Summit Commercial Ice Maker, it could be because the drainhole below the ice storage bin is blocked; remove the bin and clean the drainhole. Another potential cause is a kinked drain hose, or a drain hose improperly placed higher than the floor of the ice storage bin; ensure the drain hose allows unhindered drainage.
  • D
    douglasmitchellSep 12, 2025
    What to do if the body of my Summit Commercial BIM-44 G Ice Maker is electrified?
    • R
      Robert LewisSep 12, 2025
      If the body of your Summit Commercial Ice Maker is electrified, the ground line might not be properly connected in the socket. Use a socket meeting the grounding requirements.

Summary

Ice Maker Safety

Important Safety Instructions

Basic precautions to reduce risk of fire, electric shock, or injury.

Important Safeguards

Danger

Hazards that can result in severe personal injury or death.

Warning

Hazards that can result in extensive product damage, serious personal injury, or death.

Electrical Connection

Proper grounding, outlet requirements, and cord safety.

Technical Information

Introduction

Component Locations

Diagram and labels of major ice maker parts.

Ice Maker Installation

Unpacking

Steps for removing packaging and preparing the unit for installation.

Location Requirements

Clearance dimensions, ventilation, temperature, and water supply needs.

Electrical Requirements

Details on power supply, grounding, and outlet specifications.

Leveling the Ice Maker

How to adjust casters for proper leveling and stable operation.

Reversing the Door Swing

Step-by-step guide to change the door hinge direction.

Water Supply

Requirements for connecting water, pressure, and temperature.

Drain

How to connect the drain line for proper water removal.

Installation Types

Mobile, Enclosed, and Built-in installation methods and considerations.

Operation

Final Check List before Operation

Pre-operation checks for installation and readiness.

Operating Method

Steps to start and run the ice maker for ice production.

How the Machine Makes Ice

Explanation of the ice freeze and harvest cycles.

How the Machine Uses the Water

Details on water flow and the freezing process.

Normal Sounds

Common sounds and their causes during operation.

Preparing the Ice Maker for Long Storage

Steps for shutting down and storing the unit for extended periods.

Cleaning and Maintenance

What Parts Should Be Kept Clean

List of key components requiring regular cleaning for optimal performance.

Exterior Cleaning

How to clean the outer surfaces of the unit safely.

Interior Cleaning

How to clean the ice storage bin and water trough for hygiene.

Condenser Cleaning

How to clean the condenser for proper airflow and efficiency.

Water Distribution Tube Cleaning

How to clear blockages in the water distribution tube for consistent ice production.

Ice-Making System Cleaning

How to remove mineral scale buildup from the ice making system.

Control Panel

Description of LEDs and Buttons

Explanation of indicator lights and control buttons on the panel.

Ice Size Adjustment Guide

How to change the size of the ice cubes produced.

Major Functions

Overview of key operational features and automatic processes.

Troubleshooting

Before Calling for Service

Initial steps to take before contacting a service technician.

Troubleshooting Guide

Table of common problems, their causes, and probable solutions.

Summit Limited Warranty

Summit Commercial BIM-44 G Specifications

General IconGeneral
BrandSummit Commercial
ModelBIM-44 G
CategoryIce Maker
LanguageEnglish