How to fix motor auto-tuning fault in Sumpo Electric Co., Ltd. P9000?
- LllewisSep 23, 2025
If the Sumpo Electric Co., Ltd. Controller reports a motor auto-tuning fault because the motor cannot rotate properly, enter the motor parameters correctly.
How to fix motor auto-tuning fault in Sumpo Electric Co., Ltd. P9000?
If the Sumpo Electric Co., Ltd. Controller reports a motor auto-tuning fault because the motor cannot rotate properly, enter the motor parameters correctly.
What to do if Sumpo Electric Co., Ltd. Controller shows under-voltage?
If the Sumpo Electric Co., Ltd. Controller displays an under-voltage error, it could be due to a few reasons. There might be an instantaneous power failure on the input power supply, so you should eliminate any external power supply faults and check if the power fails during running. It's also possible that the input voltage is too low, so verify that the wiring of all power input cables is secure. In the worst case, the drive control board may have failed, in which case you should contact the agent or our.
Why is my Sumpo Electric Co., Ltd. Controller module overheating?
If the Sumpo Electric Co., Ltd. Controller is overheating, it could be due to a few reasons: the ambient temperature might be too high, the fan could be damaged, or the air filter might be blocked. To resolve this, try lowering the ambient temperature, replacing the damaged fan, or clearing the air filter.
What causes power supply phase loss in Sumpo Electric Co., Ltd. Controller?
If the Sumpo Electric Co., Ltd. Controller reports a power supply phase loss, it could be because the power input phases are not symmetric. You should check whether the three phases of the power supply are balanced and whether the power voltage is normal. If they are not, adjust the power input. It is also possible that the drive control board has failed, in that case contact the agent or our.
How to fix over-voltage during acceleration on Sumpo Electric Co., Ltd. P9000 Controller?
If the Sumpo Electric Co., Ltd. Controller indicates an over-voltage during acceleration, the input voltage might be too high, so you should adjust the input voltage. Alternatively, the regeneration power of the motor could be too high, so check the balance coefficient. It's also possible that the braking resistance is too large or the braking unit has failed, so select a proper braking resistor and check whether the resistance is too large based on the recommended braking resistance table in chapter 3. Finally, the acceleration rate might be too short, so observe whether the bus voltage is normal and whether it rises too quickly during running.
How to troubleshoot speed feedback incorrect on Sumpo Electric Co., Ltd. P9000?
If the Sumpo Electric Co., Ltd. Controller shows speed feedback incorrect, and AB signals are lost during auto-tuning, exchange any two phases of the motor UVW cables. If the phase sequence of the motor is incorrect, check that all signal cable wiring of the encoder is correct and secure.
What to do if Sumpo Electric Co., Ltd. P9000 shows door close fault?
If the Sumpo Electric Co., Ltd. Controller shows 'Door close fault', and the consecutive times that the door does not open to the limit reaches the setting in Pb-13, check whether the door machine system works properly.
What to do if Sumpo Electric Co., Ltd. P9000 shows door open fault?
If the Sumpo Electric Co., Ltd. Controller shows 'Door open fault', and the consecutive times that the door does not open to the limit reaches the setting in Pb-13, check whether the door machine system works properly.
How do I fix current control fault on Sumpo Electric Co., Ltd. P9000 Controller?
If the Sumpo Electric Co., Ltd. Controller has a current control fault because the excitation current deviation is too large, check the circuit of the encoder. If the torque limit is exceeded for a very long time, reduce the load if it is too heavy.
What causes over-current during deceleration in Sumpo Electric Co., Ltd. P9000 Controller?
If the Sumpo Electric Co., Ltd. Controller experiences an over-current during deceleration, it may be due to the main circuit output being grounded or short-circuited, improper motor auto-tuning, an excessively heavy load, or a deceleration rate that is too short.
Essential safety measures and warnings for handling the controller during operation.
General safety guidelines and warnings applicable to the controller's use and installation.
Details on the integrated protective functions for various fault conditions.
Requirements for installation environment, clearance, and mounting of the controller.
Outlines the steps for system commissioning, including checks and parameter settings.
Details on setting motor parameters and performing auto-tuning for optimal performance.
Explains emergency evacuation, parallel control, and VIP functions.
Comprehensive table listing all function codes, parameters, ranges, and properties.
Details on the five levels of fault severity and their handling procedures.
Lists common fault codes, their possible causes, and recommended solutions.
Specifies requirements for satisfying the European EMC directive for system compliance.
Provides solutions for common EMC interference problems like leakage and communication issues.