EasyManuals Logo

Sun Microsystems StorEdge 3510 Manual

Sun Microsystems StorEdge 3510
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
20 Sun StorEdge 3000 Family Best Practices Manual June 2004
6. Choose No to decline the controller reset.
7. Select channel 5.
8. Choose “channel Mode RCCOM.”
9. Choose Yes to confirm.
10. Choose No to decline the controller reset.
11. Select channel 2.
12. Choose “channel Mode drive.”
13. Choose Yes to confirm.
14. Choose No to decline the controller reset.
15. Select channel 3.
16. Choose “channel Mode drive.”
17. Choose Yes to confirm.
18. Choose Yes to reset the controller.
Cautions
Caution The UNIX and Solaris format and Solaris probe-scsi-all commands
do not display all mapped LUNs if there is not a partition or logical drive mapped to
LUN 0.
Caution Do not use both in-band and out-of-band connections at the same time to
manage the array. Otherwise conflicts between multiple operations might occur.
Caution Suspend all I/O activities and unmount filesystems before issuing
download, reset, or shutdown commands.
Caution Do not connect HBAs of different speeds to the same FC channel.
Otherwise data corruption might occur.

Other manuals for Sun Microsystems StorEdge 3510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems StorEdge 3510 and is the answer not in the manual?

Sun Microsystems StorEdge 3510 Specifications

General IconGeneral
BrandSun Microsystems
ModelStorEdge 3510
CategoryStorage
LanguageEnglish

Related product manuals