MAXEON SOLAR TECHNOLOGIES, LTD.
537620 Rev.I
©2024 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this document are subject to change without notice. 10
APPENDIX: MOUNTING CONFIGURATIONS AND LOAD RATINGS
TOP CLAMPS
GEN 5.2 FRAME PROFILE
SunPower Maxeon 5 AC Residenal Solar Panel
(SPR-MAX5-XXX-BLK-E3-AC)
SIDE FRAME PROFILE
32 mm
END FRAME PROFILE
24 mm
40 mm
A - Ground Holes (4X Ø 4.2mm)
1017 mm
1835 mm
0
0
Measurement Tolerances are +/-3mm for the Length and Width of the module.
A
0
265
514
150
714
0
265
514
150
714
350
350
40 mm
1 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
pares, unless there is a formal authorizaon by Maxeon.
3 Rails must not be under the Microinverter.
4 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
5 Boom flange mounng
6 Range indicates posioning of the clamp and not the rails
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Long Side Mounng,
Point Supported
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Perpendicular to
Mounng Frame
(End Mount)
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
265 - 514
514 - 714
0 - 150
150 - 265
265 - 514
514- 714
0 - 150
150 - 265
265 - 514
514- 714
0 - 350
0 - 350
0 - 350
+3600/-2400
+2400/-2400
+2400/-2400
+1600/-1600
+1600/-1600
+2400/-1600
+2400/-2400
+5400/-3600
+2400/-2400
+2400/-2400
+2400/-2400
+5400/-3600
+2400/-2400
+2400/-2400
+2400/-2550
+5400/-4050
+1600/-1600
+3600/-2400
+1600/-1600
+1600/-1600
+1600/-1600
+3600/-2400
+1600/-1600
+1600/-1600
+1600/-1700
+3600/-2700
Test L oad
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
363.7 mm
252.8 mm
Microinverter
Exclusion Zone