Troubleshoong
Troubleshoong Soluon
Overheat thermostat
No combuson
Waste hatch do not open
Toilet is dead on arrival
Unscrew the screws and li the top
o the toilet; check the thermostat
in the electrical unit. Remove the ashes
or paper that are outside the burning
chamber.
Bad combuson
Check all thermostats.
Check waste tray, if the tray is full,
it may cause poor combuson.
See separate point about bad
combuson.
Step down onto the pedal once more
to see if the lids close.
If not, disassemble the top of the toilet
and check the aps is connected when
the top is mounted again.
Check the distribuon fuse in your cabin
Check the fuse on the back of the toilet
Many visits?
Can cause the combuson to become
poor. Press the start buon to start the
combuson once again.
Fix the venlaon
Change the catalyst-mass
Contact service-place
Bag is stuck or the combuson
chamber is not completely closed
due to stuck bag.
Overheat thermostat or
defect element.
The lids are out of posion.
This will normally happen
if the toilet is put together
in a wrong way.
No funcon within the toilet,
and no light in the buon
To many users due to the capacity
of the toilet.
The heang element could be
broken. This should be changed
every 5 year.
Bad venlaon – check if there is
something blocking the pipes.
Catalyst mass can be dense and
should be replaced with an
interval of 1–2 years, depending
on use.
Possible cause