41
Troubleshoong
Troubleshoong Soluon
The cooling fan is running
but no combuson
The cooling fan turns on
and o periodically aer
the combuson
Burnt paper/ash outside
the ash pot
• Reset the automac fuse. Remove top
lid of the toilet assembled with 4 screws.
Change heang element
• Circuit board may be replaced
Smell in the toilet room
• No need for acon, this is normal
• Remove top lid of the toilet assembled
with 4 screws. Carefully push the lid
downwards if there is too much
resistance when you unscrew.
Remove all visible waste. Assemble
again and test.
• Check external venlaon according to
this manual’s mounng instrucons
• Check venlaon for obstrucons
• Check that the heang element is
working and adjust burning me if
necessary
• Adjust toggle clip ght enough to
hold the ash pot close to the burning
chamber
• Install more venlaon ducts in your
cabin and seal bigger gaps and ducts
between toilet room and rest of your
living area
• Disconnect the thermostat so that the
fan runs at low speed all the me for a
posive dra in the venlaon pipe.
(kit/set purchased separately).
• Heat fuse has blown
• Heat element has gone bust
• Circuit board error
• Heat fan will automacally start if
the temperature is over the cut
o limit
• One or more of the waste bags
has goen stuck in the lid of
burning chamber
• No fresh air intake, or too small
air intake in the toilet room
• Obstrucons in the venlaon
duct
• Waste that has not been properly
combusted in the burning
chamber
• Toggle clip that holds the burning
chamber in the right posion is
too loose
• Kitchen fan or replace sucks air
from the toilet room and use the
venlaon piping to get enough
airow
Possible cause