5
Maintenance of the lter
• Always disconnect from the mains supply before carrying out any maintenance!
•Cleanlterregularly,afterrstinstallation.Ifyourpondisheavilypolluted,theltersponge
shouldinitiallybecleaneddaily.Removetheltercompartmentcover(C-f) by simultaneously
pressing the catch (C-g) on both sides and lifting the cover up.
• Activated carbon absorbs color and toxins from the water and therefore becomes saturated.
Replacethelterspongeandtheltermediatwiceaseason(moreoftenifnecessary),aCombi
Clear Filter Media Set (art. 06020760) is available from your SuperFish dealer.
Maintenance of the pump and UVC-unit
• Always disconnect from the mains supply before carrying out any maintenance!
• Check monthly the operation of the UV lamp via the light indicator on the cover (C-d).
•FormaintenanceofthepumpandUVC,rstloosenandremovethespraypipe(C-a).
Press the catch (C-h) of the front cover on both sides and lift the cover up.
• The pump and the UVC-unit are connected to each other by a 90° bend, loosen one of the swivels
(D-a) to disconnect the pump from the UVC.
• Your pump needs regular cleaning. There is no warranty on failures due to dirty pumps and scale
build up inside the pump caused by improper maintenance.
• Depending on usage the rotor of your pump can get worn out and damaged, this is normal, new
rotors can be purchased at your dealer.
• The UVC device should be cleaned twice a year. As soon as algae growth increases, check the UVC
and UV-lamp and clean or exchange as needed.
•Thelampishot,wait10minutesafterswitchobeforeopeningtheunit.
• Slide the red switch lock to unlock the unit head and housing (E-a).
• Turn the unit head counter-clockwise against the stop then carefully pull it out of the housing (E-b).
• Screwotheunionnut,pullothequartzglassincludingtheOringbyaslightrotarymovement(F).
Clean the quartz glass outer face with SuperFish UVC Clean carefully and check for damage.
Replace the UV-lamp if neccessairy (Recycling).
•Insertthe(replacement)UVlamp,thenputintothelight-shelterring,atsealsandtheUVTube
clip respectively (G).
•PlacetheunitheadwiththettedUVlampandquartzglassintothehousing(H). Turn it clockwise
up to the stop and slide the red switch lock to the housing (J).
•ToavoidUVCoverheating,switchotheUVCdevicewhennowaterisowingpastit.
•Inthewinterseason,whenthesystemisnotused,theCombiClearltershouldberemovedto
avoid the risk of freezing.
• The UV-lamp should be replaced yearly.