WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
PFS
®
US
Installation and Operation Instructions
Outdoor Vent-Free Firebox
(Box only, Mosaic Masonry Brick Liner Required)
Models
VRE6036 VRE6042
VRE6050
P901010-00
P/N 901010-00 Rev. C 06/2021
Report No. F09-130
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also
contains information that will enable you to obtain replacement parts or accessory items when needed. Keep
it with your other important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to this manual for correct installation and operational procedures. For assistance or
additional information consult a qualified installer, service agency or the gas supplier.
This fireplace is approved for use on an outdoor application provided that a certified gas log set approved
under the ANSI Z21.97 standard with a maximum input rate of 40,000 BTU's is used.
An IHP hood must be
installed when using a vent-free log heater (see Parts, page 17).
DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UNLESS THIS FIREBOX MEETS THE MINIMUM DIMEN-
SIONS REQUIRED FOR THE INSTALLATION.
WARNING: FOR USE ONLY WITH A LISTED, GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO
EXCEED 40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.
Question and Answer IconNeed help?

Do you have a question about the Superior VRE6036 and is the answer not in the manual?

Overview

This document describes the Superior VRE6000 Series Vent-Free Firebox, an appliance designed for use with vent-free gas log heaters. The manual covers installation, operation, maintenance, and safety information for models VRE6036, VRE6042, and VRE6050.

Function Description:

The Superior VRE6000 Series Vent-Free Firebox is a decorative appliance intended to house a vent-free gas log heater. It provides the aesthetic appeal of a traditional fireplace without the need for a chimney or vent, making it suitable for various indoor installations. The firebox is designed to operate safely and efficiently when paired with approved vent-free gas log heaters. It includes provisions for optional accessories such as outside air kits and mosaic masonry brick panels to enhance its appearance and functionality.

Important Technical Specifications:

The VRE6000 series includes three models, distinguished by their width:

  • VRE6036: 36-inch model.
  • VRE6042: 42-inch model.
  • VRE6050: 50-inch model.

Key dimensions for the VRE6036 model include a front width of 45-1/4 inches, a depth of 29 inches, and a height of 54-1/4 inches. The hearth dimensions for the 36-inch model are 35-1/4 inches wide by 19 inches deep. For the VRE6042 model, the front width is 51-1/4 inches, depth is 30-1/8 inches, and height is 54-1/4 inches. The hearth dimensions for the 42-inch model are 41-1/8 inches wide by 23 inches deep. For the VRE6050 model, the front width is 59-1/4 inches, depth is 38-1/8 inches, and height is 54-1/4 inches. The hearth dimensions for the 50-inch model are 49-1/8 inches wide by 23 inches deep.

The firebox is designed to accommodate vent-free gas log heaters with specific BTU/hr ratings. For the 36-inch model, the maximum recommended input rate is 40,000 BTU/hr. The firebox is listed under ANSI Z21.97 standard for unvented decorative gas appliances.

Usage Features:

  • Vent-Free Operation: Eliminates the need for a chimney or vent, offering greater flexibility in installation locations.
  • Decorative Purpose: Primarily intended for aesthetic enhancement, providing the look and feel of a traditional fireplace.
  • Compatibility: Designed to be used with approved vent-free gas log heaters. Users must ensure the gas log heater's BTU/hr rating does not exceed the firebox's maximum recommended input.
  • Safety Screens and Hood: The firebox must be operated with the provided firebox screen and hood in place, and screens must be closed before running the installed gas log heater to ensure safe and efficient operation. Replacement hoods are available (J4353 for 50", J4354 for 42", J4355 for 36").
  • Optional Accessories:
    • Mosaic Masonry Brick Kits: Available in various colors and patterns (Warm Red, Ivory, Midnight, Slate Grey) and styles (Full Stacked, Split Stacked, Herr Full, Herr Split) for 36", 42", and 50" models, allowing for customization of the firebox interior. These panels are installed after the firebox is placed in its permanent location.
    • Outside Air Kits: Optional kits (AK4F for floor installation, AK4 for sidewall installation) can be purchased to provide combustion and ventilation air from outside the home, which may be required in certain installations or for improved air quality.
    • Cabinet Mantels: The firebox can be installed with a cabinet mantel, which can be purchased from a retailer or custom-built.
  • Installation Flexibility: Can be installed against a wall or directly on the floor.
  • Clearance Requirements: Specific minimum clearances to combustible materials must be maintained around the firebox, mantel, and ceiling to ensure safety. Detailed diagrams and tables are provided in the manual for these clearances.
  • Gas Line Installation: Requires proper gas piping to the firebox location, with an access hole for the gas line that will be covered by the cabinet mantel. All gas piping and connections must be tested for leaks by a qualified service person.

Maintenance Features:

  • Regular Cleaning: The manual advises keeping the firebox area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
  • Professional Servicing: Installation and servicing of gas hearth products should be performed by professionals certified by the National Fireplace Institute (NFI) as NFI Gas Specialists.
  • Brick Panel Installation: If mosaic masonry brick panels are used, they should be installed after the firebox is in its permanent location. Grouting instructions are provided, emphasizing the need to allow 72 hours for the grout to cure before operating the fireplace.
  • Part Replacement: Replacement parts should be ordered through an IHP distributor or dealer, using the model number, serial number, part number, description, quantity, and installation date. Only manufacturer-approved parts should be used.
  • Inspection: Regular inspection of the firebox and gas log heater is recommended to ensure proper operation and identify any potential issues.
  • No Unauthorized Modifications: Any changes to the firebox or its controls can be dangerous and are not recommended. Using unapproved blower inserts, heat exchanger inserts, or other accessories is prohibited.

Safety Warnings:

The manual contains numerous safety warnings, including:

  • Carbon Monoxide Poisoning: A significant danger, potentially leading to death. Proper ventilation and adherence to installation guidelines are crucial.
  • Hot Surfaces: The firebox front and screen become very hot during operation and remain hot for a time after shutdown. Children and adults should be kept away to prevent burns or clothing ignition.
  • Combustible Materials: Do not place clothing or other flammable materials on or near the appliance. Maintain specified clearances to combustibles.
  • Drafts and Flame Patterns: Avoid fans blowing directly into the firebox or any drafts that alter burner flame patterns, as this can cause sooting.
  • Lifting Hazard: The firebox is heavy, and single-person lifting can cause injury. Assistance should be used when moving or lifting the unit.
  • Unapproved Parts: Only masonry brick panels and other parts approved by IHP should be used. Substitute materials can lead to poor performance and safety hazards.
  • Ventilation Requirements: The firebox requires a specific volume of indoor combustion air. In some cases, additional permanent openings or an outside air kit may be necessary to ensure adequate ventilation, especially in tightly constructed homes.
  • Gas Leaks: All gas piping and connections must be tested for leaks by a qualified service person. Do not operate the appliance if a leak is detected.

This comprehensive manual ensures users have all necessary information for the safe and effective use of their Superior VRE6000 Series Vent-Free Firebox.

Superior VRE6036 Specifications

General IconGeneral
BrandSuperior
ModelVRE6036
CategoryIndoor Fireplace