EasyManuals Logo

Suraielec T40D User Manual

Default Icon
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Suraielec 7-Day Digital Box Timer Switch
SKU: T40D
Safety Section
WARNING
Risk of Fire or Electrical Shock
• This timer should be installed by a licensed electrician. Turn power off at the main panel before servicing this switch or setting up its controls.
• Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
• Installation and/or wiring must be in accordance with national and local electrical code requirements.
• This enclosure does not provide grounding between conduit connections. When the metallic conduit is used, you must also install grounding type
bushings and jumper wire.
• Use #14-# 8 AWG wires, rated at least 75°C (167°F)-COPPER conductors ONLY.
• Make sure there is no wire insulation under the terminal plate on the time switch connector. Firmly tighten terminal screws.
• Do not remove the insulator that is covering terminals.
• KEEP THE DOOR CLOSED AT ALL TIMES when not servicing.
• Installation, Operating and Safety Instructions - Instructions for installation and use of this product are provided by the manufacturer. "Make sure to
use this product together with 40A circuit breaker in the upstream" stated in the manual.
Specifications
Product lIlustration
Light Chart
Input
120- 240/277VAC, 60Hz Detects voltage automatically(NO DIP SWITCH SETTING REQUIRED)
Contact Ratings
- 40A Resistive 120 to 277 VAC;
- 30A General Purpose 120 to 277 VAC;
- 20A Resistive, 30VDC;
- 1HP, 120 VAC;
- 2HP, 240VAC;
- 20A Ballasted load 120 to 277 VAC;
- 15A Tungsten, 120 VAC;
- 5A Tungsten, 250VAC;
- 800VA, Pilot Duty, 120VAC;
- 720VA, Pilot Duty, 240 VAC;
- TV-5, 120VAC
Load Indicator
Power Indicator
Red
Solid
Solid
No Light
No Light
Blue
Name
Color
Status Status
FIG.1 Product IIlustration
Input normal
Input abnormal
Power is on
Power is off
Timer Indicator
Digital Timer
Clip
Load Indicator
Power Indicator
Plastic Insulator
Knockouts
1
Open the plastic insulator
Grounded Terminal
Terminal range
- #14- #8 AWG
Operating temperature:
- -40°F to 149°F
Minimum ON or OFF time
- 1 minute
Maximum ON or OFF time
- 23 hours, 59 minutes

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suraielec T40D and is the answer not in the manual?

Suraielec T40D Specifications

General IconGeneral
BrandSuraielec
ModelT40D
CategoryTimer
LanguageEnglish