Sutron Corporation 8310 & 7310 Users Manual 8800-1125Rev. 2.7 (BETA) 4/16/2014 pg. 48
RIGHT shows details
Diagnostics/Inputs
When you select Inputs, you can view the last measured value from each input. Note that the
menu lists the Measurement number, input number, I/O connection along with the value. For
most inputs, you can force a live measurement by pressing SET/ENTER. You can also Calibrate,
examine the I/O configuration, check mux settings (if used), change the setup, and view the Raw
value by pressing RIGHT.
Inputs (3)
M1.I1: AIO1:1 > 2.14989 V G
M2.I1: Battery > 13.8101 V G
M3.I1: AIO1:2 > 2.03278 V G
End Inputs
RIGHT more, ENTER measure
M2.I1: Battery
M2.I1: Calibrate 13.8101 V G
M2.I1: I/O Config Battery
M2.I1: Raw Val 13.8101 V G
M2.I1: Setup >
End Menu
ENTER to calibrate
Diagnostics/Outputs
Outputs (3)
M1.O1: Stage > 2.15 G
M2.O1: VBAT > 13.81 V G
M3.O1: AirTemp > 2.03 G
End Outputs
ENTER to measure live | RIGHT to view log
Note that the hint suggests pressing RIGHT to view the log. You can get to the logged data from
here as well as from the main menu and several other menus in the 8310.
Communications
The 8310 has built-in 4 communications ports. The status of the ports can be viewed in the
Diagnostics/Communications menu as shown below. Only those ports that have been
configured will show up in the list.
Communications (3)
COM1: (Standby-On) Direct
COM2: (Standby-On) SATLINK
LAN (Standby-On) >
Reset Com Device
End Communications
RIGHT to Test