Sutron Corporation 8310 & 7310 Users Manual 8800-1125Rev. 2.7 (BETA) 4/16/2014 pg. 64
TempUnits Celsius
SwitchedPwr > None
Processing Slope-Offset
Slope 1
Offset 0
Cal Slope 1
Cal Offset 0
M1.I1: Cur Val 23.9738 Celsius G
M1.O1*: TEMPAvg 23.981 C G
M1.O2*: TEMPMin > 23.96 G
M1.O3*: TEMPMax > 23.99 G
M1.O4*: TEMPCnt > 6.00 G
M1.O5: TEMPSTD > 0.01 G
M1.O6: TEMP > 23.97 G
End M1*: TEMP
The MeasType is Average, which produces 6 output values: Average, MIN, MAX, Count (CNT),
Standard deviation (STD), and the last sampled value. Other MeasTypes will have different
outputs.
Note that there’s an arrow on the menu item M1.O1 and the other output values for this
measurement. Press RIGHT to enter the output menu for each output shown. This is where you
choose what you want to do with each output- you can log, transmit, add processing steps,
choose the number of decimal places, and more.
The following table shows the details of each item in this menu. Note that the table has many
field dependent values. They are shown indented and are only present based on a field value
above it.
MeasName
Value: String
Description: MeasName is an editable, pre-defined string (names.txt). This name becomes the
basis of the output name.
Enable
Value: YES | NO
Description: If Enable is YES, the system will make measurements according to the setup. If
Enable=NO, no measurements will be made. This allows you to create a super setup for the
station and only enable those sensors that may be present.
MeasType
Description: The 8310 has a growing list of measurement types that provide to support special
measurement and processing needs. Each MeasType may have its own configuration
dependent values.