Sutron ACCUBAR 5600-0120-2 User Manual
50 pages
Manual
Specs
Ask a question
To Next Page
To Next Page
Loading...
22400 Davis Drive
Sterling
,
V
A 20164
(703) 406-2800
ww
w
.sutron.c
om & ww
w
.sutronwin.c
om/sutronwin/tw/
page
1
GS-25F604D SBSA
ISO 9001:2008 Certied
(703) 406-2801 F
ax
Sutron is an authorized Iridium
V
alue A
dded Reseller (VAR).
3/22/2011
SUTRON
A
C
CUBAR
®
BAROMETRIC
PRESSURE
MUL
TIPLE
INTERF
A
CE SENSOR
OPERA
TIONS
&
MAINTENANCE
MANU
AL
MODEL
5600-
0120
-1,
-
2
P
ART NO
.
8800
-
1036
REVISION F
2
Table of Contents
Default Chapter
2
Table of Contents
2
1 Introduction
4
2 Quick Start
5
3 Cabling
6
Sutron-Supplied Cable
6
Terminal Strip
6
SDI-12 Wiring
7
RS-232 Wiring
7
Analog Wiring
8
4 Setup and Operation
9
Introduction
9
Nomenclature
9
Setting the Address
9
Using Switches to Set the Address
10
Using a Command to Set the Address
10
Verifying the Address and Operation
11
Commands (Overview)
12
Making a Measurement
13
Selecting a Measurement Command Class
13
Always Supported
13
Multiple Long Measurement Time Sensors
13
Improved Data Integrity Checking
13
Making a Non-Concurrent Measurement (M Command)
13
Making a Concurrent Measurement (C Command)
15
Making a Non-Concurrent Measurement with CRC-16 (MC Command)
16
Making a Concurrent Measurement with CRC-16 (CC Command)
17
Other Measurements
19
Changing the Units
19
Setting User Units
20
Setting Station Elevation
20
Analog Output Range
21
Converting Voltage to Pressure
22
Configuring the Operating Mode and Averaging Time
23
Setting the Operating Mode
23
Setting the Averaging Time
23
Resetting the Unit to Factory Default Configuration
24
5 Command Reference
25
Accubar Basic SDI-12 Commands
25
Accubar Extended Commands
34
Additional Commands for Analog Output Units (-2)
37
6 Installation
38
7 Calibration
39
Factory Calibration
39
Metrology Lab Calibration
39
8 Troubleshooting and Maintenance
41
Troubleshooting
41
Additional Troubleshooting Commands
41
Measure Break Detect Time
41
Test Analog Output
42
Maintenance
42
9 Specifications for 5600-0120 Barometric ACCUBAR
43
Appendix A -- Introduction to Pressure Measurement
45
Appendix B- Sutron Customer Service Policy
49
Appendix C- Commercial Warranty
50
Sutron Manufactured Equipment
50
Non-Sutron Manufactured Equipment
50
Repair and Return Policy
50
Extended Warranty and On-Site Maintenance
50
Need help?
Do you have a question about the Sutron ACCUBAR 5600-0120-2 and is the answer not in the manual?
Ask a question
Sutron ACCUBAR 5600-0120-2 Specifications
General
Operating Temperature
-40°C to +85°C
Output Signal
4-20 mA
Power Supply
10-30 Vdc
Process Connection
1/4" NPT male
Accuracy
±0.1% of full scale