may be overheating protection due to
failure of temperature controller or
circuit board. Identify whether
temperature controller is normal and then
press reset button of temperature limiter.
Power on the heater again.
3.
of computer board
Replace the circuit board
Code
water
from the
heater
No screen
display
1.
Power cut
2.
Action of temperature limiter
1.
Wait for power supply
2.
Failure of temperature controller or circuit
board results in overheating protection.
Identify whether temperature controller is
normal and then press reset button of
temperature limiter. Power on the heater
again.
3.
If temperature controller is normal but
temperature limiter is activated earlier, it
needs to replace the heater because
contact betwee
n temperature tube and
heating pipe or excessive water scale
cause badness of thermal transmission.
Nonconfor
ming
heating
temperature
or little
water from
shower
head
The current temperature setting is
Raise the temperature
1. Failure of water mixing valve
2.
Failu
temperature controller
1.
Adjust the water mixing valve
2.
Replace circuit board or temperature
controller. Otherwise, it needs to replace
the heater because contact between
temperature tube and heating pipe or
water scale cause bad
ness of thermal
transmission.
No water flow from hot
water outlet
1.
Suspension of water supplies
2.
Too low water pressure
2.
not opened
4.
Failure of water mixing valve
1.
Wait for water supply
2.
Use it when water pressure rises up
3.
Open intake valve
4.
Replace intake valve
Water leakage
connection is not sealed properly
Seal the joints again
Note: E1-E4 Procedures are only applicable to the electronic product with a screen.
(I) Fault analysis and troubleshooting for shower head without hot water
For mechanically controlled type of electric water heater, drain without hot water mainly result from
circuit failure, heating pipe error and misoperation.
Electric circuit: Mainly judge the failure by considering whether temperature controller, temperature
limiter, switch and internal connection lines are normal;
Heating pipe error: Mainly resulting from circuit break of heating pipe;
Misoperation: Mainly resulting from insufficient heating time, too low temperature setting of
temperature controller, trip-out of switch of earth leakage circuit breaker, power supply and water