10 Swedstyle Memory S - EN Swedstyle Memory S - EN 11
5.2 Saving a memory position
This function saves a set table top position. One memory position can be saved
per memory position key.
1. Move the table to the desired height
2. The display shows the table top height (e.g. 73 cm)
3. Press and hold the SAVE Key after 5 seconds the display will flash
4. Now press the memory position key (e.g. 2)
5. The display shows
6. After about two seconds, the table top height is displayed again
5.3 Switching unit between cm and inch
1. Press and hold both memory buttons + and simultaneously
until the display shows . For about 5 seconds.
2 Release the keys.
a Press 1 for cm. The display shows
b Press 2 for inch. The display shows
5.4 Change sensitivity - disable S-Touch sensor
1. Press the memory keys + simultaneously for at least 3 seconds until
the display shows
2. Change sensitivity with or . You will get increased sensitivity with
a higher number, and decreased sensitivity with a lower number. 5 is standard and
0 disables S-Touch.
3. The display will light down and the new desired setting is completed.
5.5 Reset proceedure
1. Lower the frame by pressing Keep pressing for at least 8 seconds. The table will go
to its lowest position, make a beeping sound and then move up about 5 mm. It has now
reached its lower position.
2. Release the key. The reset is now complete.
S
0 73
S 2
0 73
5.6 Container stop
A function used to set a lowest or highest position to table. Used to protect e.g. a drawer
underneath the table top.
Set a highest position:
1. Move the table to the desired highest height that you want to save.
2. Press the up + down keys simultaneously, within 2-3 seconds release the down key.
3. Press the ”down” key slowly 3 times, you will hear a beep.
4. A highest position has now been saved.
Set a lowest position:
1. Move the table to the desired lowest height that you want to save.
2. Press the up + down keys simultaneously, within 2-3 seconds release the up key.
3. Press the ”up” key slowly 3 times, you will hear a beep.
4. A lowest position has now been saved.
Deactivate the container stop:
1. Move the table to the end position that you want to deactivate.
2. Repeat the same steps 2-4 as when activating the container stop. (see above)
5.7 Factory reset
A function if you want to reset all settings as a new box with factory set. NOTE! it does not reset
any changed settings regarding inch - cm.
1. Press the up + down keys simultaneously for at least 30 sec.
(After 5 seconds a beep will sound and the table will move to its absolute lowest position).
2. Hold for another 25 seconds until a long beep is heard.
S
C-I
0-9
C
I