Swift Group Select 144 - En-Route Heating

Default Icon
149 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONNECTING SERVICES
50
Changing a gas cylinder
Please use the correct size spanner for the gas
hose connectors as this will prevent damage
to the screw fittings and ensure that the fitting
is tightened sufficiently.
Turn off gas appliances
Close the empty gas cylinder’s valve
Remove the high pressure hose from the
gas cylinder.
Attach the high pressure hose to the full
gas cylinder.
Open the full cylinder’s valve.
Press the hose-break safety device and the
gas-flow monitor.
Check the hose connection to the cylinder
valve for leaks.
En-route heating
An en-route heating system is installed with
additional safety features.
! WARNING: When re-fuelling your
motorhome, switch off the heater and close
the cylinder valve.
Safety features
MonoControl CS regulator incorporating a
crash sensor which stops the gas flow in the
event of the motorhome being involved in a
traffic collision.
• Gas flow monitor
• Hose rupture protection is installed.
The full system is Homologated in compliance
with UN ECE Regulation 122
Operating instructions
Priming the gas system
• Open the cylinder’s valve. (1)
Firmly press the hose rupture protection
(green button) on the high pressure hose.
(2) If necessary (e.g. if the regulator has
been knocked when replacing a LPG
cylinder) press the green reset button on
the regulator. (3)
Start the gas-burning devices if desired.
Note: Service and repairs must only be
carried out by a competent service engineer.
Note: The regulator should be replaced no
more than ten years after manufacture.
! WARNING: To ensure the safe working
of the en-route heating any replacement
high pressure hoses must be of the same
type as originally fitted. They must have the
safety valve to ensure that the gas does not
leak out in the event of damage to the gas
pipe work in the event of a traffic collision.
! WARNING: When travelling using the
en-route system all other LPG appliance
shut off valves must be in the closed
position including the cooker, water heater
etc.