ELECTRICAL SYSTEMS
65
ELECTRICAL SYSTEMS
65
2.8 Temperature Readings
The EC800 system uses two sensors to
measure internal temperature and humidity,
and external temperature. The internal
temperature and humidity sensor is furniture
mounted within the motorhome, and the
external sensor is mounted below the
motorhome floor. The figures displayed
are for information only, and it is hoped the
information will be useful, for example when
checking temperatures remotely during cold
weather.
For vehicles fitted with Alde or Truma heating
systems, this sensor is not used to control the
heating temperature as it is measured above
the door by the Alde or Truma room sensor.
The readings on the heating system may
vary relative to the one shown on the EC800
control panel.
For vehicles fitted with a Whale heating
system, the sensor is used to control the
heating temperature as this system does not
have its own sensor.
2.9 Water System Operation
The EC800 control panel pump button
operates the internal water pump drawing
water from an on-board.
The water tanks (fresh & waste) incorporate a
level warning feature to warn the user when
the fresh water level drops below 25% or when
the waste water level reaches 100%. These
warnings can be enabled / disabled on the
control panel water screen.
If the water pump power is turned on and
the fresh water level drops to below 25% a
warning beep will be heard and a message will
be displayed on the control panel. To cancel
the warning, press the confirm button.
If the water pump power is turned on and the
waste water level rises to full (100%) a warning
beep will be heard and a message will be
displayed on the control panel. To cancel the
warning, press the confirm button.
These warnings will not be repeated unless the
water pump power switch is turned off and on
again. This is to ensure the warning does not
become a nuisance.