ZV-3299 REV A
RECOMMENDED TOOLS
Safety Glasses Measuring Tape
Level
Drill
Phillips Screwdriver
1. VALVE BODY INSTALLATION
1.1 Orient Mounting Bracket and Valve Body
Mounting bracket and valve body must
be oriented correctly to ensure successful
installation (see FIGURE 1.1).
1. Orient valve body so shower outlet ("S") is
facing upward and tub outlet ("T") is facing
downward.
2. Orient bracket so the Symmons logo is
visible in the bottom right corner.
1.2 Install Valve Body to Mounting Bracket
1. Align screw holes in bracket with screw
holes in valve body stringer mounts
(see FIGURE 1.2):
4 PORT (bottom left & top right holes)
3 PORT (top left & top right holes)
2. Place valve body into mounting bracket.
Thread (2x) screws into mounting bracket
to secure valve body (see FIGURE 1.3).
FIGURE 1.1
TUB ("T")
SHOWER ("S")
SYMMONS LOGO
1
2
FIGURE 1.3
FIGURE 1.2
3 PORT
4 PORT
Temptrol Rapid Install
™
Bracket
RTS-076
Installation Instructions