Service and Maintenance / Single Axis Valve Gate Nozzle 16SVH
10.3.2 Single Axis Valve Gate Nozzle 16SVH
Technical Data
Doc007360.png
Valve pin operation
Operation medium hydraulic
Pressure range 40 - 60 bar (580 - 870 psi)
Flowrate 2.5 l/min
Reaction time ~0,5 s
Valve pin stroke: 14 mm
Adjustment ± 1 mm
Via adjustment threads from
outside.
Closing force 4984 N / 40 bar (580 psi)
Opening force 4043 N / 40 bar (580 psi)
Connection M12x1,5 (8-L)
Valve pin
Valve pin diameter Ø 8 mm
Attachment Quick coupling, anti-rotation
Heating Power
The numbering of the heating
zones starts at the nozzle tip
and ends at the nozzle head.
Zone 1
(From a nozzle length of
100 mm)
400 Watt
Zone 2
(From a nozzle length of
120 mm)
558 - 1030 Watt
Zone 3
(From a nozzle length of
370 mm)
1188 - 1230 Watt
Head 800 plus 680 Watt
NOTICE
To ensure long life and continued flawless operation of the actuator, we recommend using a service medium that
complies with the requirements of classification 21/18/13 pursuant to ISO 4406.