3)
drum. ONLY run the motor in REV if the cutter has become caught. If the cable begins to get stuck or
buckle/kink/twist , immediately remove your foot from the foot switch while firmly holding the cable
with both hands. Allow the machine to come to a complete stop and the tension to release from the
cable. Turn the machine off and immediately manually rotate the cable in the opposite direction until
the twist or buckle has been removed.
Retrieving the cable
5)
6)
7)
8)
9.
10.
The motor switch should be OFF and machine unplugged prior to preforming any maintenance,
adjusting, or cleaning the machine to reduce the risk of electric shock, fire, serious injury or death.
Cables
Cleaning the drum machine
Lubrication
Storage
Move the AUTOFEED control handle to the F position. Do no operate the motor in reverse.
Unplug the power cord.
Loosen the thumbscrew and hand feed all the cable back into the drum, cleaning in cold water then
oiling the cable as you go. It is recommended that the cable is continuously flushed through with
clean water and oiled as it is being retrieved from the pipe and again before putting it away. This will
prolong cable life and prevent unpleasant odors as well as the damaging effects of drain cleaning
compounds.
Once all of the cable is fed back into the drum, tighten the thumbscrew.
SPECIFICATION
MACHINE MAINTENANCE
The metal cable should be thoroughly cleaned with water and lubricated to prolong cable life and
prevent unpleasant odors as well as the damaging effects of sediment and drain cleaning
compounds. Cleaning and lubricating should occur prior to storing the machine. Regularly inspect
cables for damage.
This machine is equipped with a drain hole in the cable drum. It is recommended prior to storage,
all water residues should be removed from the drum. Confirm the drum is dry prior to storing.
Typically, the drain cleaning machine will not require lubrication. The bearings will need to greased
with a general lubricant if the drum is removed or changed. The cable will need to be lubricated after
each use.
Make sure all water and residue is removed from the drum prior to storage. Drum should be stored
Line Capacity
Drum Capacity
Motor Type
Motor Rating
No Load Speed(n0)
Control
Operating Temperature
2’’-4’’(50mm-100mm) Line
75’(23m) of 1/2’’(12mm) Diameter Cable
Induction, Single Phase
120V~60Hz 5.8A
160RPM
Rocker Type FOR/OFF/REV switch and pneumatic foot switch
20°F to 140°F (-6°C to 60°C)
- 06 -