PW Series
Solenoid-driven Diaphragm Metering Pump
7 Thank you for purchasing this TACMINA product. Please read this
OPERATION MANUAL carefully in order to ensure that you will use the
product safely and correctly.
7 Be sure to keep this OPERATION MANUAL in a place where it will be
easily available for reference.
7 If the product you purchased conforms to special specifications not
described in this OPERATION MANUAL, handle the product according to
details of separate meetings, drawings and approved documents.
Please read this OPERATION MANUAL carefully before use.
Operating the pump incorrectly in disregard of these instructions
may lead to death, injury and/or cause property damage.
OPERATION MANUAL
PW/PWM/PWT
DCLPW/DCLPWM/DCLPWT
CLPW/CLPWM/CLPWT
Applicable Models
This illustration is for the PW-30R
7
TACMINA accepts no liability whatsoever for any damage caused by
malfunction of this product and other damage caused by use of this product.
00H1-4EM-127PW(E).indd2 2014/11/1711:31:59

Questions and Answers

  • B
    Brandon RothSep 5, 2025
    Why is chemical liquid leaking from the escape port of my Tacmina PW Water Pump?
    • E
      Eddie MoranSep 6, 2025
      If chemical liquid is leaking from the chemical liquid escape port of your Tacmina Water Pump: * Replace the relief valve if it hasn't been replaced after use. * Check the pressure and specifications, as an abnormal pressure may have been generated.
  • K
    kristinereyesNov 25, 2025
    Why is the discharge capacity of my Tacmina Water Pump too small?
    • S
      Sophia HernandezNov 25, 2025
      If the discharge capacity of your Tacmina Water Pump is too small, here are several possible reasons and solutions: * Air may have entered the pump head; release the air. * The diaphragm may have deteriorated or been damaged; replace it. * The valve seat area may have deteriorated or be clogged; clean or replace it. * The pipe may be clogged; clean it. * The suction height may be outside the specified range; adjust it. * The chemical liquid may be too viscous; reduce the viscosity or change to high-viscosity joints. * The discharge pressure may be too high; check the pressure and specifications. * The stroke length may be too short; increase it. * The suction-side hose or valve may be clogged; clean or replace them. * The foot valve or the strainer may be clogged; clea...
  • J
    Jill BishopSep 18, 2025
    What does error code E-02 mean on a Tacmina PW?
    • K
      kevin72Sep 18, 2025
      If E-02 is displayed on your Tacmina Water Pump, the chemical liquid remaining in the tank has dropped to a low level. Replenish the chemical liquid in the tank.
  • W
    whitney90Sep 16, 2025
    What does error code E-04 mean on a Tacmina PW?
    • S
      Sarah DominguezSep 16, 2025
      If E-04 is displayed on your Tacmina Water Pump, the buffer size has been exceeded in the pulse input-based proportional control. Review the setting and the pump model.
  • R
    rjamesSep 14, 2025
    What does error code E-05 mean on a Tacmina PW?
    • T
      timothy44Sep 14, 2025
      If E-05 is displayed on your Tacmina Water Pump, the analog input value has dropped below 2 mA or risen above 22 mA. Check the wiring connections.
  • A
    Andrew RichardsSep 12, 2025
    What does error code E-06 mean on a Tacmina PW Water Pump?
    • C
      cruzaprilSep 13, 2025
      If E-06 is displayed on your Tacmina Water Pump, it means the discharge pressure has increased to an abnormally high level. Return the piping pressure to the normal level.
  • D
    danielgreenSep 12, 2025
    How to unlock the keys on my Tacmina PW?
    • M
      Mia WilliamsonSep 12, 2025
      If the keys on your Tacmina Water Pump cannot be operated, release the key lock.
  • C
    Catherine DouglasSep 9, 2025
    What to do if my Tacmina Water Pump cannot receive pulse input?
    • N
      Natalie LambertSep 9, 2025
      If your Tacmina Water Pump is not receiving pulse input: * Check the signal cable for disconnections. * Verify the signal input specifications are correct.
  • S
    Samuel StephensSep 7, 2025
    Why does the actual discharge capacity differ from the set value on my Tacmina PW?
    • M
      Maria GonzalezSep 7, 2025
      If the actual discharge capacity of your Tacmina Water Pump differs significantly from the set value in manual mode: * The wrong maximum discharge capacity may have been set; perform calibration and set the maximum value correctly. * The stroke length may be different from when the maximum value was set; set the stroke length to the necessary value and then set the maximum value correctly.
  • M
    Michelle CoxAug 21, 2025
    How to troubleshoot a Tacmina Water Pump that does not turn on?
    • S
      Samantha MirandaAug 21, 2025
      If your Tacmina Water Pump isn't turning on and the display is dark, here's what to check: * **Power Supply:** Ensure the pump is connected to the correct power supply and voltage. * **Wiring:** Inspect all wiring connections to the pump for any issues and correct them. * **Power Cable:** Check the power cable for any damage. * **Main Power:** Make sure the main power supply is properly connected. * **Breaker:** Check if the breaker has tripped; if so, find out why and reset it. * **Circuit:** There may be a circuit malfunction, in which case, replace the circuit.

Summary

How to Operate the Pump Safely

Installation, Piping & Connections

Covers guidelines for installing the pump, connecting pipes, and electrical wiring.

Electrical Wiring

Connecting the Power Supply & Protective Earth

Instructions for connecting the pump's power and grounding wires.

Operation

Operating Precautions

Essential safety guidelines and checks before, during, and after pump operation.

Discharge-Volume Setting

Methods for adjusting the pump's discharge capacity via stroke number or length.

Air Releasing

Procedures for removing air from the pump head and lines to ensure proper function.

Calibration

Function to accurately set discharge capacity by measuring actual output.

Description of Functions

Pump Control Functions

Details on various control modes like manual, timer, and pulse input for pump operation.

Parameter Settings

Configuration options for pump behavior, alarms, and operational modes via parameters.

Maintenance

Maintenance Precautions

Safety guidelines and general checks for performing maintenance tasks on the pump.

Troubleshooting

Troubleshooting Guide

Common problems, causes, and solutions for pump malfunctions during operation.

Specifications

Performance Specifications

Technical data including discharge volume, pressure, speed, and environmental ratings.

Setting Flows

PW Series: Standard (Pulse) Type Setting Flow

Step-by-step guide for setting up the PW series pump in standard pulse mode.

PWM Series: Analog Type Setting Flow

Step-by-step guide for setting up the PWM series pump in analog mode.

Tacmina PW Series Specifications

General IconGeneral
BrandTacmina
ModelPW Series
CategoryWater Pump
LanguageEnglish