Listings/Approvals:
UL Guide (NKPZ) for industrial control
equipment per UL Standard 508 Industrial
Control Equipment
UL Guide (MFHX) for heating/cooling ap-
pliance switch per UL Standard 353 Limit
Controls
CSA Class (321106) for industrial control
equipment per CSA Standard C22.2 No.
14-M Industrial Control Equipment
Maximum Service Pressure: 250 PSI
Enclosure:
NEMA Type 1 (For indoor use only)
Formed sheet metal with powdercoat finish.
Not for use in hazardous locations.
Contacts:
IFS01: One SPDT (Form C) switch
IFS02: Two sets of SPDT (Form C) switches
to provide versatility in wiring two separate
circuits.
15 Amps at 125/250VAC
.5 Amps at 125VDC
.25 Amps at 250VDC
Motor Ratings : 120VAC 240VAC
Horsepower : 1/8 1/4
AC F.L.A. : 3.8 2.9
AC L.R.A. : 22.8 17.4
Pilot Duty Rating : 125 VA 120/240 VAC
IFSH1/2 Contacts:
IFSH1: One SPDT (Form C) switch
IFSH2: Two sets of SPDT (Form C) switches
to provide versatility in wiring two separate
circuits.
22 Amps at 125/250VAC
Motor Ratings : 120VAC 240VAC
Horsepower : 1/2 1
AC F.L.A. : 9.8 8.0
AC L.R.A. : 58.8 48.0
Pilot Duty Rating : 125 VA 120/240 VAC
Ambient Temperature Range:
32°F/176°F (0°C/80°C)
Media Temperature Range:
32°F/250°F (0°C/121°C)
Pipe Connections:
1" NPT Brass on models IFSxxB
1" NPT 316 Stainless Steel on models
IFSxxS
Conduit Entrance: Two openings for 1/2" conduit
Usage: For pipe sizes 1" - 8"
Caution: This device is not intended for applica-
tions in explosive environments.
Note: IFSW Series available with NEMA 4 enclo-
sure for outdoor use. (See bulletins
#102-026 & #102-027 or Catalog 100-8.2).
GENERAL
The Model IFS is a flow switch used in liquid
flow lines carrying water or any fluid not harmful
to brass, stainless steel, EPDM or fluorosilicone,
and not classified as a hazardous fluid.
This switch can serve as a way to start and stop
electrically operated equipment when a flow or no
flow condition occurs in a variety of applications.
This device is designed for use only as an operat-
ing control. Where an operating control failure
would result in personal injury and/or loss of prop-
erty, it is the responsibility of the installer to add
devices (safety, limit controls) that protect against,
or systems (alarm, supervisory systems) that warn
of control failure.
Instruction Sheet
Industrial Flow Switch
SUPERCEDES: 102-122 DATED January 1, 2002
# 5401110-REV E
EFFECTIVE: March 17, 2004
102-022
(IFS01 &
IFS02 ONLY)
Question and Answer IconNeed help?

Do you have a question about the Taco IFS01BF-1 and is the answer not in the manual?

Taco IFS01BF-1 Specifications

General IconGeneral
BrandTaco
ModelIFS01BF-1
CategorySwitch
LanguageEnglish

Summary

Listings and Approvals

UL Guide (NKPZ)

For industrial control equipment per UL Standard 508.

UL Guide (MFHX)

For heating/cooling appliance switch per UL Standard 353.

CSA Class (321106)

For industrial control equipment per CSA Standard C22.2 No. 14-M.

Enclosure Details

Type

NEMA Type 1 for indoor use only.

Construction

Formed sheet metal with powdercoat finish.

Hazardous Locations

Not for use in hazardous locations.

Contacts and Specifications

IFS01 IFS02 Contacts

Single or double SPDT switches, 15A at 125/250VAC, 0.5A at 125VDC.

IFSH1 IFSH2 Contacts

Single or double high current SPDT switches, 22A at 125/250VAC.

Motor Ratings

Horsepower, FLA, and LRA for different voltage ratings.

Pilot Duty Rating

125 VA at 120/240 VAC.

Temperature Ranges

Ambient 32-176°F, Media 32-250°F.

Pipe Connections

1" NPT Brass or Stainless Steel.

Conduit Entrance

Two openings for 1/2" conduit.

Mounting and Installation

Mounting Orientation

Horizontal or vertical upward flow, avoid downward flow.

Pipe Location

5 pipe diameters straight run, avoid adjacent fittings.

Paddle Selection and Trim

Use appropriate paddle size or trim for pipe diameter.

Paddle Orientation

Flat at right angle to flow, bushing arrow points in flow direction.

Sensitivity Adjustment

Turn screw clockwise to increase, counter-clockwise to decrease flow rate.

Wiring and Adjustment

Wiring Requirements

Use rated wire, follow NEC and local regulations.

Switch Action Diagrams

Illustrates switch action for IFS01/IFS02 and IFSH1/IFSH2.

Adjustment Procedure

Remove cover, adjust sensitivity screw, replace cover.

Operation Check

Verify "no-flow" operation and restore rate.

Specifications and Ordering

Typical Flow Rates

GPM required to actuate switch for various pipe sizes.

IFS Model Ordering

Codes for process connection, bushing material, and model type.

Paddle Kit Ordering

Codes for paddle style.