PROBLEM SOLUTIONS
WATER HEATER
Unit does not ignite
when water goes
through the unit.
 Is the flow rate over 0.5 GPM (1.9 L/min)? (p. 41)
 Check the filter on the cold water inlet. (p. 46)
 Check for reverse connection and cross connection.
 If you use the remote controller, is the power button turned on?
 Check if the inlet water temperature is too high. If it is too close to
the set temperature, the water heater won't work.
 Is the gas supply turned on?
 Is power available to the unit? If so, is the power button on the
controller or inside the water heater turned on?
The fan motor is
still spinning after
operation has stopped.
 This is normal. After operation has stopped, the fan motor keeps
running from 15 to 70 seconds in order to re-ignite quickly, as well
as purge all the exhaust gas out of the flue.
Unit sounds abnormal
while in operation
 Contact the manufacturer at 1-877-737-2840.
Buit-in controller
and remote controller
Built-in and remote
controller do not
display anything when
the power button is
turned on.
 Make sure the unit is supplied with power.
 For the remote controller: Make sure the connection to the unit is
correct. (pp. 30 and 31)
When the
controller turned
ON, STAND BY LED
is lit.
Buit-in controller
 When the unit has not operated for five minutes or more, the
display turns off to conserve energy.
 Although the controller of the parent unit will display the set
temperature at the Easy-Link System, the controller of the child
unit will not display the set temperature.
An ERROR code is
displayed.
 Please see pp. 49 to 52.
EASY-LINK SYSTEM
510U model only
How are the unit
numbers assigned?
 For an Easy-Link System, the Parent unit is always labeled #1 and all
other subsequent Child units are numbered randomly.
 To check which numbers are assigned to which Child units, push the
button on the computer board of any Child unit as shown below.
The unit number will be displayed on the controller of each Child
unit. (Refer to p. 33.)

Troubleshoong
Owner's Guide

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takagi AT-K5U-OS and is the answer not in the manual?

Takagi AT-K5U-OS Specifications

General IconGeneral
BrandTakagi
ModelAT-K5U-OS
CategoryWater Heater
LanguageEnglish

Related product manuals