Purpose of the Manual
This manual will assist the reader in the operation of the appliance safely and
efficiently. It should be kept within close proximity of the appliance for easy access.
All staff must have read and understood this manual in its entirety before operating or
undertaking maintenance. Anyone operating the appliance should have also
received training by the manufacturer or authorised representative. Failure to do so
can result in severe injury or death.
This manual has been written to ensure the safe operation and maintenance of the
appliance but does negate from on site Health and Safety requirements. The owner
of the appliance and operator should undertake all necessary risk assessments.
The pictures contained within this manual are only intended to assist the operator
and may differ from the parts used on your appliance.
Operators must also follow safety labels on the appliance, as well as safety advice
written within this manual.
Introduction to the T-Range
The Talbott’s T-Range heaters are completely of British manufacture and feature a
carefully designed double heat exchange system for maximum efficiency. The
combustion chamber or fire box has a full ceramic lining retained with stainless steel
giving full protection up to 1,500 deg C (2,700 Deg F). The flue gases then flow from
the combustion chamber through a triple pass secondary heat exchange before
entering the flue. This arrangement ensures that the maximum amount of heat is
extracted from the waste wood being burnt.
T-Range Operation
Combustion air is supplied by a small fan and is distributed evenly over the entire
length of the combustion chamber by a heavy gauge steel tube giving complete
balanced combustion.
Each heater is supplied with air distribution heads of a swivel louvered type as
standard. These can be rotated and the vanes adjusted to ensure the optimum
direction of hot air flow.
The Handfed T-Range models are manually fed by loading fuel through the loading
door at the front of the appliance.