"TAN Bead” Nucleic Acid Extractor
(Non-Sterile)
Maelstrom 9600 LH
User Manual
Question and Answer IconNeed help?

Do you have a question about the TAN Bead Maelstrom 9600 LH and is the answer not in the manual?

Summary

1. Introduction

Operation Principle

Explains how Maelstrom 9600 LH uses magnetic rods and spin tips for nucleic acid extraction.

Intended Use

Describes the intended applications of Maelstrom 9600 LH with TANBead kits for DNA/RNA extraction.

Environmental Requirements

Outlines the necessary environmental conditions for optimal instrument operation and lifespan.

Safety Instructions and Guidelines

Provides essential safety precautions for operating the Maelstrom 9600 LH with biohazardous materials and chemicals.

2. Overview

Instrument Specifications

Details technical specifications of the Maelstrom 9600 LH, including model, weight, dimensions, and power.

Controller Views

Illustrates the back view of the controller, highlighting connectors and switches.

Extraction Platform Details

Shows the side view of the extraction platform and describes the shield plate with sensors.

Control Panel Elements

Details sensor regulators and provides an overview of the control panel and its buttons.

3. Installation

4. Get Started

Initial Controller Navigation

Guides users through navigating the controller display and viewing program lists.

Program Selection and Confirmation

Details the step-by-step process for selecting, confirming, and setting up programs.

Program Execution Steps

Describes program execution steps, including temperature settings, tip mounting, and plate placement.

Program States and Tip Ejection

Explains program states (RUNNING, PAUSE, END) and the procedure for ejecting spin tips.

5. Edit Program

PC Connection and AutoMag Setup

Details PC connection requirements and guides users on starting the AutoMag software.

AutoMag Program Editing

Explains how to edit program parameters using the AutoMag software, detailing each parameter.

Sample Programs and Key Functions

Presents sample programs (SHORTTEST, EJECT-TIP) and describes key functions within the AutoMag interface.

Program Transmission

Details program transmission between the PC and the M9600 LH controller using import/export functions.

6. Communication

Modbus Communication Setup

Details the setup and use of Modbus communication, including software and transmission cables.

M9600 LH and Liquid Handling System Communication

Outlines the communication protocol and sequence between the M9600 LH and a liquid handling system.

CRC Communication Protocol

Details the data formats and commands used for CRC communication, including internal keys and register reading.

7. Product Performance

Consistency and Yield Data

Explains consistency and presents performance data for nucleic acid yield and A260/A280 ratio.

Reproducibility and Yield Data

Defines reproducibility and presents performance data for nucleic acid yield and A260/A280 ratio across cycles.

8. Cleaning and Maintenance

9. Disposal

10. Patent

11. Appendix

Transport Recommendations

Advises on using EPE buffer materials to protect the mechanism during transport.

TAN Bead Maelstrom 9600 LH Specifications