66
-
Incorrect charging characteristics or the use of inappro-
priate chargers may result in early failure or the quick
destruction of batteries.
-
-
- Standard value: At least approx. 20% of the available
capacity should be used up before recharging the bat-
tery.
-
-
- Before recommissioning, the batteries should under-
go another complete charging cycle.
-
-
The user may be injured by electric shock.
Disconnecting the charger while it is still switched on
may result in an explosion in the battery compartment.
- Do not use the charger if there are any signs of dam-
age to the plug, cable or device connection.
-
-
• Connect the external battery charger with the battery
charging plug of the machine.
• The machine must be switched off.
• Connect the main cord with a socket (protected by slow
fuse).
• The yellow indicator is constantly lit
until approx. 90% of the battery ca-
pacity has been reached. After-
wards, the indicator flashes until the
battery is fully charged.
• When the charging process is com-
plete, the green indicator is lit.
• Stow away the power cord for (optional) on-board chargers
in the provided compartment.
• Store the charging cable in a dry place where it is protected
against damage.