This symbol means that the product may
have batteries or batteries inside it,
which must be removed before
disposing of the product. Remember that
batteries must be disposed of in special autho-
rized containers. And they should never be
thrown into the re.
Model AC2600RVKT
Rated capacity for cooling (P
rated
for cooling) 2,676 kW
Rated capacity for heating (P
rated
for heating) 2,415 kW
Rated power input for cooling (P
EER
) 1,017 kW
Rated power input for heating (P
COP
) 1,037 kW
Rated Energy efciency ratio (EER
d
) 2,63
Power consumption in thermostat-off mode (P
TO
) 2,33
Power Consumption in Standby mode (P
SB
) N/A
Electricity consumption of single/double duct appliances (Q
DD
, Q
SD
) Cooling:
Q
SD
: 1,017 kWh/h
Heating:
Q
SD
: 1,037 kWh/h
Sound Pressure level (L
WA
) 65 dB(A)
Global warming Potential (GWP) 3 kgCO
2
eq.
INSTRUCTIONS FOR REPAIR-
ING APPLIANCES CONTAIN-
ING R290
GENERAL INSTRUCTIONS
CHECKS TO THE AREA
- Prior to beginning work on systems containing
ammable refrigerants, safety checks are nec-
essary to ensure that the risk of ignition is mi-
nimised. For repair to the refrigerating system,
the following precautions shall be complied with
prior to con-ducting work on the system.
WORK PROCEDURE
- Work shall be undertaken under a controlled
procedure so as to minimise the risk of a am-
mable gas or vapour being present while the
work is being performed.
GENERAL WORK AREA
- All maintenance staff and others working in
the local area shall be instructed on the nature
of work being carried out. Work in conned
spaces shall be avoided. The area around the
workspace shall be sectioned off. Ensure that
the conditions within the area have been made
safe by control of ammable material.
CHECKING FOR PRESENCE OF REFRIGERANT
- The area shall be checked with an appropriate
refrigerant detector prior to and during work,
to ensure the technician is aware of potentially
ammable atmospheres. Ensure that the leak
tection equipment being used is suitable for use
with ammable refrigerants, i.e. nonsparking,
adequately sealed or intrinsically safe.
PRESENCE OF FIRE EXTINGUISHER
- If any hot work is to be conducted on the
refrigeration equipment or any associated parts,
propriate re extinguishing equipment shall be
available to hand. Have a dry powder or CO 2
re extinguisher adjacent to the charging area.
NO IGNITION SOURCES
- No person carrying out work in relation to a
refrigeration system which involves exposing
any pipe work that contains or has contained
ammable refrigerant shall use any sources
of ignition in such a manner that it may lead to
the risk of re or explosion. All possible ignition
sources, including igarette smoking, should
be kept sufciently far away from the site of
installation, repairing, removing and disposal,
during which ammable refrigerant can possibly

Questions and Answers: