6
Warning! Read safety information before connecting the Cyclone 1320 LED to AC
mains power.
Warning! For protection from electric shock,the Cyclone 1320 must be
grounded(earthed).The power distribution circuit must be equipped with a fuse or
circuit breaker and ground-fault(earth-fault)protection.
Warning!Socked outlets or external power switches used to supply the Cyclone 1320
with power disconnected from power.
Important!Do not use an external dimming system to supply power to the Cyclone
1320,as this may cause damage to the fixture that is not covered by the product
warranty.
Power Voltage
Warning!Check that the voltage range specified on the fixture serial number label
matches the local AC mains power voltage before applying power to fixture.
The Cyclone 1320 has an auto-ranging power supply that accepts mains power at
100-240VAC nominal,50/60Hz,do not apply AC mains power at any other voltage or
frequency to the fixture.
The Cyclone 1320 can draw significant peat currents during normal use,to avid
overload,allow one 16 or 20amp branch circuit per fixture to operate at full power,two
fixtures may be placed on a 16 amp branch circuit,but considerations for the type of
MCB(Miniature Circuit Breaker)must also be respected:16 A type C will fit most needs.
Power cable and Power plug
The Cyclone 1320 power input cable must meet the requires listed under Protection from
electric shock,keep cable runs as short as possible.
If you install a power plug on the power cable for connection to an AC power outlet,install a
grounding-type plug with an integral cable grip that is rated 250V,20A minimum,in the EU
the plug must be rated 250V,16A minimum,follow the plug manufactures instructions,the
table shows standard wire color-coding schemes and some possible pin identifications
schemes;if pins are not clearly identified,or if you have any doubts about proper
installation,consult a qualified electrician.
Wire Color
(EU models)
Wire color
(US models)
Conductor
Symbol
Screw(US)
Brown
Black
Live
L
Yellow or brass
Blue
White
Neutral
N
Silver
Yellow/Green
Green
Ground(Earth)
Green