- 15 -
1.6. Connect and tighten the electrode cable to the positive pole. Use the electrode
holder to clamp the electrode.
1.7. Turn the machine on - the power indicator lights up and the fan becomes
operational.
1.8. Set the parameters for the welding job. The welding current is set in
accordance with welding rod specifications. (See table below).
1.9. Commence welding using short-circuit arc ignition.
1.10. Complete the operation following the normal procedure. During the operation
the parameters can be adjusted to suit the situational demands.
1.11. After completion of the operation, turn off the power using the switch on the
rear panel of the machine.
2. Table Guideline for MMA Electrode Specification and Welding Current
Maintenance
Safe operation of the machine is dependent on regular maintenance and the
replacement of worn and defective parts where necessary.
1. Daily Precautionary Checks
1.1. For any abnormal vibrations, sounds or odours.
1.2. For any sign of overheating on cable connections.
Electrode diameter
mm
Welding current range
A
Welding Voltage range
V
Φ1.6
44~84
21.8~23.4
Φ2.0
60~100
22.4~24.0
Φ2.5
80~120
23.2~24.8
Φ3.2
108~148
23.3~24.9
Φ4.0
140~180
24.6~27.2
Φ5.0
180~220
27.2~28.8
Φ6.0
220~260
28.8~30.4