PAGE 2
PAGE 7
Page 2 Page 7
DO NOT connect
to a plug & socket outlet.
WIRING DIAGRAM - MAINS SUPPLY
COLOUR CODING:
L - Live = Brown
N - Neutral = Blue
- Earth = Green & Yellow
2
2
2
OUTSIDE
ZONES
2
ZONE
1
0.75m
2.25m
3.0m
0.6m
0.6m
0.75m
IEE Bathroom Zones Diagram
Distances from a bath tub or shower tray
Bathroom fittings are subject to the appropriate zones in accordance with IEE
Regulations. This product is only suitable for permanent indoor installation in Zone 2
and outside zones. (See above) This product is not suitable for installation in Zone 0
or 1, saunas, steam rooms or shower cubicles. Do not connect to a trailing plug and
socket. Do not install onto surfaces that are either damp or electrically conductive.
Bathroom Zones
Electrical Safety
Suitable for UK Installations only.
All fittings must be installed by a competent person, in accordance with current IEE
wiring regulations. If in doubt consult a qualified electrician.
Important: Always switch off the electrical supply at the mains before installation and
maintenance. It is recommended that the fuse is withdrawn or the circuit breaker is
switched off for the necessary circuit before installation commences.
This product is manufactured to class I category and must have an earth connection.