TAV.EQU.01.RF
Tavistock Ltd, Brassmill Lane Trading Estate, Bath, BA1 3JF
| Tel: 01225 787870 | www.tavistock-bathrooms.co.uk
Installation Instructions for Equalise Backlit Mirror
Please read carefully before you start and retain for future reference
Equalise
SBL17
2
2
2
2
OUTSIDE
ZONES
Z
O
N
E
2
Z
O
N
E
1
0.75m
2.25m
3.0m
0.6m
0.6m
0.6m
0.75m
IEE BATHROOM ZONES DIAGRAM
IMPORTANT
MIRROR LOCATION
4 Pin
Connector
Retaining
Clip
T9 40W Circular
Fluorescent Tube
SAFETY INSTRUCTIONS
(Applicable to UK Installations only)
All fittings must be installed by a competent person, in accordance
with current IEE wiring regulations. If in doubt, consult a qualified
electrician.
IMPORTANT
Always switch off the electrical supply at the mains during
installation and maintenance. It is recommended that the fuse is
withdrawn or the circuit breaker is switched off for the necessary
circuit before installation commences.
The product must be mounted a minimum of 150mm from an
adjacent wall or obstruction to ensure correct function of the
infrared sensor. The sensor can be repositioned if required. See
overleaf for details.
Fitting in Bathrooms is subject to the appropriate location (See
Diagram). Refer to IEE Regulations. This product is suitable for
Zones 2 and outside zones. It IS NOT suitable for installation in
Zone 0 or Zone 1. It is also not suitable for installation in Saunas,
Steam Rooms or Shower Cubicles.
This product is only suitable for permanent installation. DO NOT
connect to a trailing plug and socket outlet.
Although this product has an Ingress Protection rating of IP44, it is
only suitable for indoor use.
Do not attach the product to surfaces that are damp or otherwise
electrically conductive.
The product should be positioned well away from curtains and other
fabrics. Never cover the mirror.
Always ensure that the correct bulb is used and that the maximum
bulb rating is not exceeded.
This product is heated, we recommend that it is turned off after use
and should never be left on for prolonged periods of time.
CARE & SAFETY
REMEMBER
Wear suitable eye protection when drilling. Take care when using
power tools near water - the use of a residual current device (RCD)
is advised. Beware of hidden cables or pipes. Take care if drilling
on tiled surfaces in case the drill slips. A piece of masking tape
applied to the wall before marking out the fixing holes will stop the
drill from wandering.
WARNINGS
Do not strike glass components with hard or pointed items. Do not
place very hot or very cold items against or in close proximity to
glass surfaces unless an adequately thick insulation material is
used to prevent such items coming in contact with the glass.
The nominal thickness of the mirror glass used in this product is
5mm and is film backed for safety. If the glass becomes chipped or
broken, replace immediately. For details on replacement glass and
other components contact customer services at the address below.
This product could be dangerous and installation is only to be
carried out by a competent person.
It is recommended that the unit is cleaned with a soft dry cloth
when turned off. Never use cleaning agents or abrasive materials
on any type of surface finish. Do not allow moisture to come into
contact with the lamp.
COMPLIANCE
This product complies with the following Electrical Safety
Standards:
EN 55015:2001; BS EN 60598-1: 2004, AMD:2001, AMD:2003; BS EN
60598-2-1: 1989. EN 60529: 1992 & A1, A2, A3.
REPLACING LAMPS
WARNING
Disconnect the unit from the mains power supply before attempting
to replace a lamp. Fluorescent lamps may get hot. Ensure lamps
are sufficiently cooled before changing. Remove the mirror glass
from the body by removing the screws and washers. Disconnect the
heated pad by
separating the small plug from the socket and store the
mirror in a safe place. Then
pull out the 4-Pin connector that locates
on the circular fluorescent tube and gently pull out the expired
lamp from the
retaining clips.
Fit
the
replacement tube in the retaining clips, making sure that it
is secure, and push the 4 pin connector onto the lamp.
Reconnect the heated pad and replace the glass front making
sure all screws are secure.
LAMP TYPE:
T9 40W Circular Fluorescent Tube.
150mm
Minimum distance
Infrared sensor
Question and Answer IconNeed help?

Do you have a question about the Tavistock Equalise and is the answer not in the manual?

Tavistock Equalise Specifications

General IconGeneral
BrandTavistock
ModelEqualise
CategoryIndoor Furnishing
LanguageEnglish

Summary

Safety and Installation Precautions

Electrical Safety and Installation

Ensure installation by a competent person, switching off mains power. Follow IEE wiring regulations.

Sensor and Location Requirements

Mount minimum 150mm from walls for sensor. Suitable for bathroom Zones 2 & outside; not Zones 0/1, Saunas, Steam Rooms.

Usage and Maintenance Cautions

Permanent installation only. Indoor use only. Avoid damp surfaces. Keep away from fabrics. Check bulb rating. Turn off heated mirror after use.

Product Care and Warnings

General Care and Safety

Wear eye protection when drilling. Use RCD with power tools near water. Beware hidden cables. Avoid slips on tiled surfaces.

Glass Component Warnings

Do not strike glass with pointed items. Use insulation for hot/cold items near glass surfaces.

Cleaning and Material Contact

Clean with a soft dry cloth. Avoid cleaning agents or abrasives. Keep moisture away from the lamp.

Technical Compliance and Lamp Replacement

Electrical Safety Standards

Product complies with EN 55015, BS EN 60598-1, BS EN 60598-2-1, EN 60529 standards.

Lamp Replacement Procedure

Disconnect power. Cool lamps. Remove glass, disconnect heated pad, detach 4-pin connector, replace tube, reconnect.

Installation Procedure

Parts Included and Preparation

Check parts list. Ensure wall is strong. Seal unused drain hole with grommet. Mount portrait or landscape.

Mirror Mounting and Drilling

Mark height, drill holes for wall plugs. Feed power cable through grommet. Secure mirror body.

Electrical Connections

Turn off power. Remove connection box cover. Connect wires (L-Brown, N-Blue, Earth-G&Y) to terminals. Tighten connections.

Final Assembly and Operation

Reconnect heated pad. Replace mirror body, ensuring correct bracket alignment. Turn power back on. Use sensor to switch.