TAVRIDA ELECTRIC ISM_LD Series Specifications

General IconGeneral
BrandTAVRIDA ELECTRIC
ModelISM_LD Series
CategoryCircuit breakers
LanguageEnglish

Summary

Introduction

Glossary

Defines abbreviations and technical terms used in the manual for clarity.

Scope of the Document

Outlines the purpose of the guide and the products covered, ISM_LD series breakers.

Design and Method of Operation: ISM and CM

Details the construction of the Indoor Switching Module (ISM) and Control Module (CM).

Receiving, Handling, and Storage

Receiving Procedures

Information on ISM and CM package contents, handling symbols, and labels.

Transport Guidelines

Instructions for safe transportation of ISM and CM units.

Handling and Incoming Inspection

Steps for checking products for damage and verifying completeness upon receipt.

Rating Plates and Warranty Seals

Guidance on checking rating plates and warranty seals for delivered devices.

Installation

General Preparation and Safety

Adherence to regulations, qualified personnel, and handling precautions during installation.

Installation of the ISM

Details on mounting positions, fixing points, and busbar connections for the ISM.

Protective Earthing

Requirements for connecting the ISM metal housing to the earth arrangement for safety.

Mechanical Interlocking

Interfaces and conditions for mechanical interlocking mechanisms with the ISM.

CM Installation and Connections

Secondary Connections of the ISM

Wiring details for auxiliary switches and actuator coils on three-phase ISM types.

CM Connections

Terminal arrangements for CM1501_01, CM16_1, and CM16_2 control modules.

CM_16 Series Factory Programmable Options

Overview of programmable settings for CM_16 series control modules.

Installation of Secondary Cables

Recommendations for installing shielded secondary cables between ISM and CM.

Switching and Control Functions

Basic Functions of Control Modules

Details on capacitor charging, Ready/Malfunction LEDs, and dry contact operations.

ISM Forced Trip by Undervoltage Relay

Functionality for tripping the ISM due to auxiliary power supply voltage drop.

Operations Counter

Information on tracking circuit breaker operations using pulse counters.

Antipumping and Blocking Duties

Rules and logic for antipumping, blocking, and combined blocking/antipumping duties.

Commissioning, Operation, Maintenance

Safety During Commissioning

Safety precautions for qualified personnel during commissioning, operation, and maintenance.

Commissioning Procedures

Tests and checks for primary and secondary parts before and after installation.

Maintenance Requirements

Guidelines for maintenance-free operation and cleaning of the ISM.

Non-conformity Handling

Procedures for addressing and reporting any non-conformities during product lifecycle.

Signalling

LED Indicators and Dry Contacts

Description of LED indicators and dry contact outputs for status and malfunction signals.

Malfunction Indication Table

Table detailing malfunction blink codes, causes, and elimination recommendations.

Product Line

Indoor Switching Modules (ISM)

Overview of available ISM types, their specifications, and former product codes.

Control Modules (CM Series)

Details on CM15 and CM16 series control modules, including voltage and functionality.

Dimensions and Weights

Dimensions and Weights of ISM

Provides detailed drawings and weight specifications for three-phase and single-phase ISM.

Dimensions and Weights of the CM

Presents dimensional drawings and weight data for CM15 and CM16 series control modules.

Circuit Diagrams

ISM_LD with CM_16_1 Control Module Diagram

Mandatory control connection diagram for ISM_LD with CM_16_1.

ISM_LD with CM_1501_01 Control Module Diagram

Mandatory control connection diagram for ISM_LD with CM_1501_01.

Technical Data

Indoor Switching Modules (ISM) Data

Technical specifications for ISM according to ANSI C37.09 standard.

Indoor Switching Modules (ISM) - Additional Standards

Technical data for ISM based on C37.74 and C37.60 standards.

Control Modules Data

Technical specifications for CM1501_01, CM16_1, and CM16_2 control modules.

Control Modules EMC and Inputs

Electromagnetic compatibility and input specifications for CM series modules.

Regulations and Ambient Conditions

Applicable Regulations and Standards

Lists standards that the ISM fulfills and relevant directives.

Ambient Conditions

Specifies environmental limits for temperature, humidity, and water vapour pressure.

Installation Altitude Correction

Guidance on adjusting dielectric strength measurements based on installation altitude.

Legal Information

Warranty and Quality Regulations

Details warranty period, conditions, and quality certifications like ISO 9001.

Complaints, Transport Damage, and Liability

Procedures for handling complaints, transport damage, and limitations of liability.

Environmental Friendliness and Non-Conformity

Information on materials, disposal, and the non-conformity reporting process.

Copyright and Documentation Usage

Restrictions on using, copying, and distributing the documentation.

Related product manuals