M134 Alignment Procedures
A. Enter Factory Mode:
Simply press the “SERVICE” key on the factory remote handset.
Press
1
2
3
4
5
6
7
8
9
0
NOTEBOOK,CAPS, DISPLAY ,SLEEP, CALENDAR ,COLOR/INS
FAVORITE,RECALL
, you can switch in the sub-menus of
FAC01
FAC18
in turns.
Press
P+
P-
to choose the items.
Press
V+
V-
to adjust the data.
Press
OK
and
P+
P-
to switch in the sub-menus of
FAC19
FAC23
.
Exit Factory Mode:
Press the “SERVICE” key on the factory remote handset. All changes in factory data will be saved in
EEPROM automatically.
Some special modes:
Aging Mode
Be used for aging before adjustment in Factory Mode.
Vertical doesnt Work
Be used for Screen & Focus voltage adjustment. In Factory
Mode, press
TV/AV
to enter and exit.
White balance adjustment Mode
Be used for White balance adjustment. In Factory
Mode, press
BUS OFF
to enter and exit.
Default Value OK mode
Be used for default value setting before TV leaves Factory. In
Factory Mode, press “S. EFFECT” to enter default value.
“Wait” will be displayed in screen, when it is finished,
“OK” will be displayed. It will exit factory mode
automatically.
Note: Now press “SERVICE” cannot enter factory mode, you
have to take the following steps to enter:
1. Setting Volume to Zero.
2. Press “V-” in cabinet and Press “Display” in RC
simultaneously.
B. Adjustment Way
1. B
Adjustment
Apply Philips Test pattern signal in normal status, adjusting VR821 to make B+=
+=+=
+=130V±
±±
±0.5V.
2. RF AGC adjustment:
Observe monitor the collector waveform of Q101 with the probe of Oscilloscope as illustration
below. Select channel 2 (>70dB) from the antenna input. Enter D-mode, select menu6 to adjust
RFAGC item until the monitor peak value to 0.8Vp-p.