EasyManua.ls Logo

TCL TCA-36CHRA/DV - Page 24

TCL TCA-36CHRA/DV
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC Inverter Air
Coil
mm
761×252×38.1
761×252×50.8
length×height×width
Number of circuits
6
6
Fan System
Indoor air circulation(Cooling/Heating)
L/S
m3/h
1100/900/700
1300/1100/900
Indoor fan type
Centrifugal
Centrifugal
Connections
Connecting
Liquid
mm
6.35
9.52
Pipe
Gas
mm
12.7
15.88
Max. height drop (high head)
m
15
30
Max. length of connecting pipe
m
30
50
Refrigerant charge with long pipe
g/m
22
50
Drainage Pipe
mm
O.D32
O.D 32
Others
Net dimensions
(W x H x D)
mm
920×210×570
920×270×570
Net weight
kg
23
27
Packing dimensions (W x H x D)
mm
1115×280×690
1115×340×690
Gross weight
kg
23
26
Note
Specifications are based on the following conditions:
Cooling: Indoor temperature 27 DB/19WB,and outdoor temperature
35 DB/24 WB.
Heating: Indoor temperature 20 DB/15WB,and outdoor temperature 7 DB/6 WB.
Voltage:220V.
Sound Level: Indoor unit sound pressure level,measured at a point 1.5m downward from the unit center.
Outdoor unit sound pressure level,measured at a point 1.0m in front of the unit.
Optional simple wired controller; Universal remote controller; auto‐restart(optional); Timer:only one circle.
Due to ongoing product development, specifications are subject to change without notice.
Model
TCA‐36D2HRA/DV
TCA‐48D2HRA/DV3
TCA‐60D2HRA/DV3
Type
Control type
Remote Controller
Static pressure
Standard
Pa
80
100
100
Range
0~80
0~100
0~100
Capacity
Btu/h(W)
36000(10550)
48000(14000)
60000(17500)
Cooling
Input
W
3050
4180
5420
capacity
Current
A
15.0
8.2
9.5
EER
W/W
3.46
3.35
3.23
Heating
Capacity
Btu/h(W)
40000(11700
53000(15530)
63000(18400)
Input
W
3224
4440
5460
capacity
Current
A
15.5
9.1
10.1
24/ 113

Table of Contents