Covers first-time power-on behavior and how to adjust the refrigerator's gear settings.
This document is a service manual for the TRF-315W refrigerator, manufactured by TCL Home Appliances (HeFei) Co., Ltd. It provides detailed information on the product's structure, operation, refrigeration system, electrical control, and maintenance.
The TRF-315W is an air-cooled double-door refrigerator. Its upper section functions as the refrigerating chamber, while the lower section is the freezer chamber. The refrigerator is designed to store food items, keeping them fresh in the refrigerating chamber and frozen in the freezer chamber. It utilizes an air-cooled system to maintain consistent temperatures throughout its compartments.
The manual distinguishes between two models: TRF-315WEXA+ (external display) and TRF-315WEA+ (internal display). While both are air-cooled double-door refrigerators, they differ in their display type and specific component part numbers.
Key components and their quantities:
Refrigeration System: The refrigeration system comprises a compressor, condenser, dry filter, capillary tube, finned-type evaporator, dew-proof tube, and evaporation coil. The compressor circulates the refrigerant, which is cooled in the condenser, filtered by the dry filter, and then expands through the capillary tube into the finned-type evaporator and evaporation coil to absorb heat from the refrigerator compartments. The dew-proof tube helps prevent condensation.
Electrical Control System: The electrical control system includes:
Initial Power-on: Upon first power-on, the refrigerator will automatically start running in Gear 5 for both TRF-315WEA+ (internal display) and TRF-315WEXA+ (external display) models.
Gear Adjustment (TRF-315WEA+ internal display): Temperature adjustment is done by repeatedly pressing the "+" or "-" keys. The refrigerator cycles through "02" → "04" → "05" → "06" → "08" → "02". The selected gear is confirmed after 5 seconds of no key operation.
Gear Adjustment (TRF-315WEXA+ external display): When the child lock is not active, pressing the "Temperature control switch" key cycles the refrigerating chamber temperature through "02" → "04" → "05" → "06" → "08" → "Power cool" → "Smart" → "Energy saving" → "02". The selected gear is confirmed after 5 seconds of no key operation.
Special Modes (TRF-315WEXA+ external display):
Power Off Memory: Both models retain their last operating state before a power outage. Upon power restoration, the refrigerator resumes operation according to the previously set parameters.
Child Lock Function (TRF-315WEXA+ external display): If there's no key operation for 30 seconds, the child lock activates, and the display screen enters screen saver mode (goes out). The first keystroke wakes up the display. To unlock, press and hold the "Temperature control switch" key for 3 seconds.
Door Alarm: If the refrigerating chamber door remains open for more than 1 minute, an alarm will sound. Pressing any key temporarily stops the alarm, but it will resume after 1 minute if the door is still open. Closing the door tightly stops the alarm.
Compressor Control: The compressor turns on when refrigeration is needed and off otherwise. There's a minimum 8-minute downtime requirement before the compressor can restart.
Light Control: The refrigerating light turns on when the door is opened and off when closed. It will also turn off automatically if it remains on continuously for more than 5 minutes.
Fan Control: The freezer fan operates whenever the compressor is on during normal refrigeration. It turns off when the compressor stops, during freezing and defrosting processes, and if the refrigerating door is detected as open.
Defrosting Heater Control: The steel tube heating wire activates during defrosting and remains off in all other states.
Failure Running Program:
The manual provides a maintenance guide focusing on user-related issues and their solutions.
Installation Environment:
Usage:
Troubleshooting (Compressor does not work):
Troubleshooting (Excessive noise):
Troubleshooting (Compressor does not stop for a long time):
The manual includes detailed diagrams for the exploded view of the product structure, refrigeration system, compressor wiring, and electrical control, along with visual guides for the removal and installation of the top light assembly and air duct assemblies in both refrigerating and freezing compartments. These visual aids are crucial for technicians performing maintenance and repairs.
| Energy Efficiency Class | A+ |
|---|---|
| Color | White |
| Number of Doors | 2 |
| Model | TCL TRF-315WEA+ |
| Total Net Capacity | 315 liters |