Key
in
"B4".
Then
the
write
error
count
(write
retry
count)
is
indicated
in
hexadecimal
notation
to
the
display
of
SOB.
(g)
Check
if
the
write
error
count
is
less
than
SO
in
hexadecimal
notation
(12S
in
decimal
notation).
Remark
The
write
error
count
changes
greatly
depending
upon
the
status
of
the
work
tape
used.
Therefore,
the
above-
mentioned
value
is
a
reference
value.
(h)
Key
in
"A4".
The
tape
is
rewound
up
to
BOT
and
the
indicator
RDY
on
SOB
lights
up.
(i)
Key
in
"BO".
The
MTU
starts
a
read
error
test.
(j)
After
the
completion
of
the
read
error
test,
the
transfer
block
count
is
indicated
in
hexadecimal
notation
to
the
display
of
SOB.
Therefore,
check
if
it
agrees
with
the
transfer
block
count
obtained
in
the
write
error
test.
(k)
Key
in
"B2",
and
"B3".
Then,
EXCEPTION
STATUS
is
indicated
to
the
display
of
SOB.
Check
if
the
display
is
"SEAO".
Key
in
"B4".
Then,
the
read
error
count
(read
retry
count)
is
indicated
in
hexadecimal
notation
to
the
display
of
SOB.
(1)
Check
if
the
read
error
count
is
less
than
1.
Remark
The
read
error
count
changes
greatly
depending
upon
the
status
of
the
work
tape
used.
Therefore,
the
above-mentioned
value
is
only
a
reference
value.
- 4075 -