(g) Check
and
adjust
the
head
alignment
in
accordance
with
Item
4-3-8.
(h)
Check
the
AGC
operation
in
accordance
with
Item
4-3-9.
(i)
Check
and
adjust
the
read
preamplifier
level
in
accordance
with
Item
4-3-14.
(j)
Check
and
adjust
the
read
level
in
accordance
with
Item
4-3-15.
(k)
Check
the
feed
through
in
accordance
with
Item
4-3-16.
(1)
Check
for
the
resolution
in
accordance
with
Item
4-3-17.
(m)
Check
for
the
erase
level
in
accordance
with
Item
4-3-18.
(n)
Check
the
peak
shift
in
accordance
with
Item
4-3-19.
(0)
Check
the
asymmetry
in
accordance
with
4-3-20.
(p)
Attach
the
PCBA
Interface
Control
in
accordance
with
4-4-10.
(q)
Attach
the
protector
guide
in
accordance
with
Item
4-2-3.(2).
(r)
Perform
the
overall
check
in
accordance
with
Item
4-3-22.